DNB Engineering, Inc.

NVLAP Lab Code: 200653-0


Address and Contact Information:

3535 W. Commonwealth Ave.
Fullerton, CA 92833
Contact: Mr. Michael Neis
Phone: 714-870-7781
Fax: 714-870-5081
E-Mail: miken@dnbenginc.com
Send E-Mail to Laboratory: DNB Engineering, Inc.
URL: http://www.dnbenginc.com

NVLAP Accreditation Information

Listed below is the scope of accreditation for this laboratory as of April 18, 2014. For additional information, contact NVLAP at (301) 975-4016.

Send E-Mail to NVLAP at: NVLAP@nist.gov


Electromagnetic Compatibility & Telecommunications

Accreditation Valid From: January 1, 2014 Through: December 31, 2014

  • Emissions Test Methods

[12/1399-30] MIL-STD 1399 Section 300A
Interface standard for Shipboard Systems: Electric Power, Alternating Current

[12/160C21] RTCA/DO-160C (1989)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 21: Emission of Radio Frequency

[12/160D21] RTCA/DO-160D (1997)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 21 - Emission of Radio Frequency Energy

[12/160F21] RTCA/DO-160F (2007)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 21 - Emissions of Radio Frequency Energy

[12/60E213] RTCA DO-160E
Section 21.3, RF Emissions, Conducted

[12/60E214] RTCA DO-160E
Section 21.4, RF Emissions, Radiated

[12/60G214] RTCA DO-160G
Section 21.4, RF Emissions, Conducted

[12/60G215] RTCA DO-160G
Section 21.5, RF Emissions, Radiated

  • Immunity Test Methods

[12/160C15] RTCA/DO-160C (1989)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 15 - Magnetic Effect

[12/160C16] RTCA/DO-160C (1989
Environmental Conditions and Test Procedures for Airborne Equipment - Section 16 - Power Input

[12/160C17] RTCA/DO-160C (1989)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 17 - Voltage Spike

[12/160C18] RTCA/DO-160C (1989)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 18 - Audio Frequency Conducted Susceptibility - Power Inputs

[12/160C19] RTCA/DO-160C (1989)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 19 - Induced Signal Susceptibility

[12/160C20] RTCA/DO-160C (1989)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 20 - Radio Frequency Susceptibility (Radiated and Conducted)

[12/160C22] RTCA/DO-160C (1989)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 22 - Lightning Induced Transient Susceptibility

[12/160D15] RTCA/DO-160D (1997)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 15 - Magnetic Effect

[12/160D16] RTCA/DO-160D (1997)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 16 - Power Input

[12/160D17] RTCA/DO-160D (1997)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 17 - Voltage Spike

[12/160D18] RTCA/DO-160D (1997)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 18 - Audio Frequency Conducted Susceptibility - Power Inputs

[12/160D19] RTCA/DO-160D (1997)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 19 - Induced Signal Susceptibility

[12/160D20] RTCA/DO-160D (1997)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 20 - Radio Frequency Susceptibility (Radiated and Conducted)

[12/160D22] RTCA/DO-160D (1997)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 22 - Lightning Induced Transient Susceptibility

[12/160D23] RTCA/DO-160D (1997)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 23 - Lightning Direct Effects

[12/160D25] RTCA/DO-160D (1997)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 25 - Electrostatic Discharge (ESD)

[12/160F15] RTCA/DO 160F (2007)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 15 - Magnetic Effect

[12/160F16] RTCA/DO-160F (2007)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 16 - Power Input

[12/160F17] RTCA/DO-160F (2007)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 17 - Voltage Spike

[12/160F18] RTCA/DO-160F (2007)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 18 - Audio Frequency Conducted Suspceptibility - Power Inputs

[12/160F19] RTCA/DO-160F (2007)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 19 - Induced Signal Susceptibility

[12/160F20] RTCA/DO-160F (2007)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 20 - Radio Frequency Susceptibility (Radiated and Conducted)

[12/160F22] RTCA/DO-160F (2007)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 22 - Lightning Induced Transient Susceptibility

[12/160F23] RTCA/DO-160F (2007)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 23 - Lightning Direct Effects

[12/160F25] RTCA/DO-160F (2007)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 25 - Electrostatic Discharge (ESD)

[12/60E15] RTCA DO 160E
Section 15, Magnetic Effects

[12/60E16] RTCA DO160E
Section 16, Power Input

[12/60E17] RTCA DO-160E
Section 17, Voltage Spikes

[12/60E18] RTCA DO-160E
Section 18, Audio Frequency Conducted Susceptibility

[12/60E19] RTCA DO-160E
Section 19, Induced Signal Susceptibility

[12/60E204] RTCA DO-160E
Section 20.4, RF Susceptibility, Conducted

[12/60E205] RTCA DO-160E
Section 20.5, RF Susceptibility, Radiated

[12/60E22] RTCA DO-160E
Section 22, Lightning Induced Transient Susceptibility

[12/60E23] RTCA DO-160E
Section 23,Lightning Direct Effects

[12/60E25] RTCA DO-160E
Section 25, Electrostatic Discharge (ESD)

[12/60G16] RTCA DO-160G
Section 16, Power Input

[12/60G17] RTCA DO-160G
Section 17, Voltage Spikes

[12/60G18] RTCA DO-160G
Section 18, Audio Frequency Conducted Suspectibility-Power Inputs

[12/60G19] RTCA DO-160G
Section 19, Induced Signal Susceptibility

[12/60G204] RTCA DO-160G
Section 20.4, RF Susceptibility, Conducted

[12/60G205] RTCA D0-160G
Section 20.5, RF Susceptibility, Radiated

[12/60G22] RTCA DO-160G
Section 22, Lightning Induced Transient Susceptibility

[12/60G23] RTCA DO-160G
Section 23,Lightning Direct Effects

[12/60G25] RTCA DO-160G
Section 25, Electrostatic Discharge (ESD)

  • MIL-STD Test Methods

[12/1399a] MIL-STD1399 Section 070
Interface standard for shipboard systems, Section 070 - Part 1- DC Magnetic Field Environment

  • MIL-STD-462 : Conducted Emissions

[12/A01]
MIL-STD-462 Method CE01

[12/A04]
MIL-STD-462 Method CE02

[12/A06]
MIL-STD-462 Method CE03

[12/A08]
MIL-STD-462 Method CE04

[12/A10]
MIL-STD-462 Method CE06

[12/A12]
MIL-STD-462 Method CE07

[12/A13]
MIL-STD-462 Version D Method CE101

[12/A14]
MIL-STD-462 Version D Method CE102

[12/A15]
MIL-STD-462 Version D Method CE106

[12/A16]
MIL-STD-461 Version E Method CE101

[12/A17]
MIL-STD-461 Version E Method CE102

[12/A18]
MIL-STD-461 Version E Method CE106

[12/A19]
MIL-STD-461 Version F Method CE101

[12/A20]
MIL-STD-461 Version F Method CE102

[12/A21]
MIL-STD-461 Version F Method CE106

  • MIL-STD-462 : Conducted Susceptibility

[12/B01]
MIL-STD-462 Method CS01

[12/B02]
MIL-STD-462 Method CS02

[12/B04]
MIL-STD-462 Method CS03/CS04/CS05

[12/B05]
MIL-STD-462 Method CS06

[12/B06]
MIL-STD-462 Method CS07

[12/B07]
MIL-STD-462 Method CS09

[12/B08]
MIL-STD-462 Method CS10

[12/B09]
MIL-STD-462 Method CS11

[12/B10]
MIL-STD-462 Method CS12

[12/B11]
MIL-STD-462 Method CS13

[12/B12]
MIL-STD-462 Version D Method CS101

[12/B13]
MIL-STD-462 Version D Method CS103

[12/B14]
MIL-STD-462 Version D Method CS104

[12/B15]
MIL-STD-462 Version D Method CS105

[12/B16]
MIL-STD-462 Version D Method CS109

[12/B17]
MIL-STD-462 Version D Method CS114

[12/B18]
MIL-STD-462 Version D Method CS115

[12/B19]
MIL-STD-462 Version D Method CS116

[12/B20]
MIL-STD-461 Version E Method CS101

[12/B21]
MIL-STD-461 Version E Method CS103

[12/B22]
MIL-STD-461 Version E Method CS104

[12/B23]
MIL-STD-461 Version E Method CS105

[12/B24]
MIL-STD-461 Version E Method CS109

[12/B25]
MIL-STD-461 Version E Method CS114

[12/B26]
MIL-STD-461 Version E Method CS115

[12/B27]
MIL-STD-461 Version E Method CS116

[12/B28]
MIL-STD-461 Version F Method CS101

[12/B29]
MIL-STD-461 Version F Method CS103

[12/B30]
MIL-STD-461 Version F Method CS104

[12/B31]
MIL-STD-461 Version F Method CS105

[12/B32]
MIL-STD-461 Version F Method CS106

[12/B33]
MIL-STD-461 Version F Method CS109

[12/B34]
MIL-STD-461 Version F Method CS114

[12/B35]
MIL-STD-461 Version F Method CS115

[12/B36]
MIL-STD-461 Version F Method CS116

  • MIL-STD-462 : Radiated Emissions

[12/D01]
MIL-STD-462 Method RE01

[12/D02]
MIL-STD-462 Method RE02

[12/D03]
MIL-STD-462 Method RE03

[12/D04]
MIL-STD-462 Version D Method RE101

[12/D05]
MIL-STD-462 Version D Method RE102

[12/D06]
MIL-STD-462 Version D Method RE103

[12/D07]
MIL-STD-461 Version E Method RE101

[12/D08]
MIL-STD-461 Version E Method RE102

[12/D09]
MIL-STD-461 Version E Method RE103

[12/D10]
MIL-STD-461 Version F Method RE101

[12/D11]
MIL-STD-461 Version F Method RE102

[12/D12]
MIL-STD-461 Version F Method RE103

  • MIL-STD-462 : Radiated Susceptibility

[12/E01]
MIL-STD-462 Method RS01

[12/E02]
MIL-STD-462 Method RS02

[12/E03]
MIL-STD-462 Method RS03 (Consult laboratory for field strengths available)

[12/E04]
MIL-STD-462 Method RS03 employing RADHAZ procedures for high level testing (Consult laboratory for field strengths available)

[12/E05]
MIL-STD-462 Method RS05

[12/E07]
MIL-STD-462 Method RS06

[12/E08]
MIL-STD-462 Version D Method RS101

[12/E09]
MIL-STD-462 Version D Method RS103

[12/E10]
MIL-STD-462 Version D Method RS105

[12/E11]
MIL-STD-461 Version E Method RS101

[12/E12]
MIL-STD-461 Version E Method RS103

[12/E13]
MIL-STD-461 Version E Method RS105

[12/E15]
MIL-STD-461 Version F Method RS101

[12/E16]
MIL-STD-461 Version F Method RS103

[12/E17]
MIL-STD-461 Version F Method RS105

Return to NVLAP Program Listing