Technology Services, National Voluntary Laboratory Accreditation Program, NIST Go to Technology Services Home Page Go to NIST Home Page Go to National Voluntary Laboratory Accreditation Program Home Page Go to Directory of Accredited Laboratories Go to Fields of Accreditation Go to Publications/Applications Go to Mutual Recognition Arrangements Go to Assessor Resources Contact National Voluntary Laboratory Accreditation Program

US Air Force Radiation Dosimetry Laboratory

NVLAP Lab Code: 100548-0


Address and Contact Information:

AFIOH/SDRR/Radiation Dosimetry Lab.
2350 Gillingham Drive
Brooks City - Base, TX 78235-5103
Contact: Mr. Gerald M. Achenbach
Phone: 210-536-5569
Fax: 210-536-5368
E-Mail: gerald.achenbach@brooks.af.mil
Send E-Mail to Laboratory: USAF, Inst. for Oper. Health AFIOH/SDRD
URL: http://www.brooks.af.mil/afioh/Laboratories

NVLAP Accreditation Information

Listed below is the scope of accreditation for this laboratory as of November 28, 2008. For additional information, contact NVLAP at (301) 975-4016.

Send E-Mail to NVLAP at: NVLAP@nist.gov


Ionizing Radiation Dosimetry

Accreditation Valid From: April 1, 2008 Through: March 31, 2009

This facility has been evaluated and deemed competent to
process the radiation dosimeters listed below employing the
Panasonic automatic readers model UD-7900M for the
whole-body dosimeters and the Harshaw 6600 Automatic TLD
Reader for the EXT-RAD & DXT-RAD extremity dosimeters.

This facility is accredited to process the following
dosimeters by virtue of actual demonstration of compliance
with ANSI HPS N13.11-2001 through whole body testing.

Panasonic TLD model UD802AT in ISA model 820-C hanger for
ANSI-HPS-N13.11-2001 categories IB, IC, IIA, IIIA, IVA, VAA,
and VICA.

Panasonic TLD model UD802AT in ISA model 811 neutron hanger
for ANSI-HPS-N13.11-2001 categories IIA, IVA, VICA.

Panasonic TLD model UD802AT in UD874 hanger for ANSI
N13.11-2001 categories IB, IC, IIA, IIIA, IVA, VAA, VICA.

Thermo Electron EPD-2 (electronic dosimeter) for
ANSI-HPS-N13.11-2001 categories IIA, IIB, IIIA, IVA, VAA.

Thermo Electron EPD-N2 for ANSI N13.11-2001 categories IA,
IIA, IVA, VICA.

By actual demonstration of compliance with ANSI HPS
N13.11-2001, the deployable Field Laboratory to Assess
Radiation Exposures (FLARE) has been evaluated and deemed
competent to process the radiation dosimeters listed below.

Thermo Electron EPD-2 (electronic dosimeter) for ANSI HPS
N13.11-2001 categories IIA, IIB, IIIA, VIA, VAA

Thermo Electron EPD N-2 (electronic dosimeter) for ANSI HPS
N13.11-2001 categories IA, IIA, IVA, VICA

This facility is accredited to process the following
extremity dosimeters by actual demonstration of compliance
with ANSI HPS N13.32-1995 through testing.

Harshaw EXT-RAD extremity TLD-100 chip in a finger ring
strap for ANSI HPS N13.32-1995 categories IVA, VA, and VIIA

Return to NVLAP Program Listing


Return to top of page NVLAP Home | Accredited Laboratories | Fields of Accreditation | Publications/Applications |
Mutual Recognition Arrangements | Assessor Resources | Contact NVLAP
Return to top of page

For questions concerning the National Voluntary Laboratory Accreditation Program, contact us:

National Voluntary Laboratory Accreditation Program, Standards Services Division, NIST, 100 Bureau Drive, Stop 2140, Gaithersburg, MD 20899-2140
Phone: (301) 975-4016, Fax: (301) 926-2884, Email: NVLAP@nist.gov

Date created: July 26, 2002
Last Updated: November 28, 2008