Technology Services, National Voluntary Laboratory Accreditation Program, NIST Go to Technology Services Home Page Go to NIST Home Page Go to National Voluntary Laboratory Accreditation Program Home Page Go to Directory of Accredited Laboratories Go to Fields of Accreditation Go to Publications/Applications Go to Mutual Recognition Arrangements Go to Assessor Resources Contact National Voluntary Laboratory Accreditation Program

Electro Magnetic Test, Inc.

NVLAP Lab Code: 200147-0


Address and Contact Information:

1547 Plymouth Street
Mountain View, CA 94043
Contact: Mr. Jay Gandhi
Phone: 650-965-4000
Fax: 650-965-3000
E-Mail: jgandhi@emtlabs.com
Send E-Mail to Laboratory: Electro Magnetic Test, Inc.
URL: http://www.emtlabs.com

NVLAP Accreditation Information

Listed below is the scope of accreditation for this laboratory as of November 1, 2009. For additional information, contact NVLAP at (301) 975-4016.

Send E-Mail to NVLAP at: NVLAP@nist.gov


Electromagnetic Compatibility & Telecommunications

Accreditation Valid From: April 1, 2009 Through: March 31, 2010

  • Emissions Test Methods

[12/610006c] EN 61000-6-3 (2001) and IEC 61000-6-3 (1996)
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments

[12/610006d] EN 61000-6-4 (2001) and IEC 61000-6-4 (1997)
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments

[12/CIS11ab] CNS 13803 (2003)
Limits and methods of measurement of electromagnetic interference characteristics of industrial, scientific an medical (ISM) radio-frequency equipment

[12/CIS14c] CNS 13783-1
Electromagnetic Compatibility Requirements for household appliances, electric tools and similar apparatus - Part 1: Emissions

[12/CIS15bc] CNS 13439 (2004)
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

[12/CIS22] IEC/CISPR 22 (1997) & EN 55022 (1998) + A1(2000)
Limits and methods of measurement of radio disturbance characteristics of information technology equipment

[12/CIS22a] IEC/CISPR 22 (1993) and EN 55022 (1994)
Limits and methods of measurement of radio disturbance characteristics of information technology equipment, Amendment 1 (1995) and Amendment 2 (1996)

[12/CIS22b] CNS 13438 (1997)
Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment

[12/CNS757] CNS 14757-2 (1992-07)
Uninterruptible power systems (UPS) - Part 2: Electromagnetic Compatibility (EMC) requirements

[12/EM02a]
IEC 61000-3-2, Edition 2.1 (2001-10), EN 61000-3-2 (2000), and AS/NZS 2279.1 (2000): Electromagnetic compatibility (EMC) Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <= 16 A)

[12/EM03] IEC 61000-3-3(1995); EN 61000-3-3(1995); AS/NZS 2279.3(1995)
EMC - Part 3: Limits - Section 3. Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current up to 16A

[12/FCC15b] ANSI C63.4 (2003) with FCC Method 47 CFR Part 15, Subpart B
Unintentional Radiators

[12/KCC0839] KCC Notice 2008-39
Korea Technical Requirements Electromagnetic Interference (EMI)

[12/KN16] Korea RRA Notice No. 2008-11 (Dec. 16, 2008)
Conformity Assessment Procedures for Electromagnetic Interference using KN 16-1-1, KN 16-1-2, KN 16-1-3, KN 16-1-4, KN 16-1-5, KN 16-2-1, KN 16-2-2, KN 16-2-3, KN 16-2-4 (2008-05)

[12/KN22] KN22 with RRL Notice No. 2005-82 (Sept. 29, 2005)
RRL Notice No. 2005-82: Technical Requirements for Electromagnetic Interference Annex 8 (KN-22), RRL Notice No. 2005-131: Conformity Assessment Procedures for Electromagnetic Interference

[12/KN22d1] KN22 (Annex 8) with RRA Announce 2008-11 (Dec. 16, 2008)
Conformity Assessment Procedure for Electromagnetic Interference; With KN 22 (Annex 8)

[12/T51a] AS/NZS CISPR 22 (2004)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

  • Immunity Test Methods

[12/610006a] EN 61000-6-1 (2001)
Electromagnetic compatibility (EMC) - Part 6 - 1: Generic standards - Immunity for residential, commercial and light-industrial environments

[12/610006b] EN 61000-6-2 (2001)
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments

[12/CIS24a] EN 55024 and CISPR 24 (1997, modified)
Information technology equipment - Immunity characteristics - Limits and methods of measurements

[12/CIS24b] AS/NZS CISPR 24 (2002)
Information technology equipment - Immunity characteristics - Limits and methods of measurement

[12/CIS24d] IEC/CISPR 24 (1997) & EN 55024 (1998) + A1 (2001), A2 (2002)
Information technology equipment - Immunity characteristics - Limits and methods of measurements

[12/I01] IEC 61000-4-2, Ed. 1.2 (2001); EN 61000-4-2
Electrostatic Discharge Immunity Test

[12/I02] IEC 61000-4-3, Ed. 2.0 (2002-03); EN 61000-4-3 (2002)
Radiated Radio-Frequency Electromagnetic Field Immunity Test

[12/I03] IEC 61000-4-4(1995), A1(2000), A2(2001); EN 61000-4-4
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical Fast Transient/Burst Immunity Test

[12/I04] IEC 61000-4-5, Ed. 1.1 (2001-04); EN 61000-4-5
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test

[12/I05] IEC 61000-4-6, Ed. 2.0 (2003-05); EN 61000-4-6
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields

[12/I06] IEC 61000-4-8, Ed. 1.1 (2001); EN 61000-4-8
Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test

[12/I07] IEC 61000-4-11, Ed. 1.1 (2001-03); EN 61000-4-11
Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests

[12/KCC0838] KCC Notice 2008-38
Korea Technical Requirements for Electromagnetic Susceptability (EMS)

[12/KN11] KN 61000-4-11 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests

[12/KN2] KN 61000-4-2 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Electrostatic Discharge Immunity Test

[12/KN24d1] KN 24 (Annex 11) RRA Announce 2008-12 (Dec. 16, 2008)
Conformity Assessment Procedure for EMS (Information technology equipment – Immunity characteristics – Limits and methods of measurement)

[12/KN2d1] KN 61000-4-2 (Annex 1); RRA Announce 2008-12 (Dec. 16, 2008)
Conformity Assessment Precedure for EMS (Electrostatic Discharge Immunity Test)

[12/KN3] KN 61000-4-3 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Radiated, radio-frequency, electromagnetic field immunity test

[12/KN3c1] KN 61000-4-3 (Annex 2) RRA Announce 2008-12 (Dec. 16, 2008)
Conformity Assessment Procedure for EMS (Radiated, radio-frequency, electromagnetic field immunity test)

[12/KN4] KN 61000-4-4 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Electromagnetic compatibility (EMC): Testing and measurement techniques - Electrical Fast Transient/Burst Immunity Test

[12/KN4c1] KN 61000-4-4 (Annex 3) RRA Announce 2008-12 (Dec. 16, 2008)
Conformity Assessment Procedure for EMS (Electrical Fast Transient/Burst test)

[12/KN5] KN 61000-4-5 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Surge Immunity Test

[12/KN5c1] KN 61000-4-5 (Annex 4) RRA Announce 2008-12 (Dec. 16, 2008)
Conformity Assessment Procedure for EMS (Surge Immunity Test)

[12/KN6] KN 61000-4-6 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Electromagnetic compatibility (EMC): Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields

[12/KN6c1] KN 61000-4-6 (Annex 5); RRA Announce 2008-12 (Dec. 16, 2008)
Conformity Assessment Procedure for EMS (Conducted disturbances, induced by radio-frequency fields test)

[12/KN8] KN 61000-4-8 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Power Frequency Magnetic Field Immunity Test

[12/KN8c1] KN 610004-8 (Annex 6) RRA Announce 2008-12 (Dec. 16, 2008)
Conformity Assessment Procedure for EMS (Power Frequency Magnetic Field Immunity Test)

[12/RRA0812] RRA Notice 2008-12 (Dec. 16, 2008)
Conformity Assessment Procedure for Electronic Susceptibility (K only)

  • Product Safety Test Methods

[12/60601aa] IEC 60601-1-2, Ed 2.1 (2004-11) & EN 60601-1-2 (2002)
Medical electrical equipment - Part 1-2: General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and tests

[12/61326a] EN 61326 (1997), A1 (1998), A2 (2001)
Electrical equipment for measurement, control and laboratory use - EMC requirements

  • Telecommunications Test Methods

[12/300386g] ETSI EN 300 386 V1.4.1 (2008-02)
Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirements

[12/CS03a] Industry Canada CS-03, Issue 9, Amendment 1 (2005)
Compliance Specification for Terminal Equipment, Terminal Systems, Network Protection Devices, Connection Arrangements and Hearing Aids Compatibility

[12/KR15] MIC Notice No. 2004-15 (March 18, 2004)
Technical Requirements for Telecommunications Terminal Equipment

[12/T01]
Terminal Equipment Network Protection Standards, FCC/ACTA Method - 47 CFR Part 68 - Analog and Digital

[12/T01a]
68.302 (Par. c,d,e,f) Environmental simulation; 68.304 Leakage current limit.; 68.306 Hazardous voltage limit.; 68.308 Signal power limit.; 68.310 Longitudinal balance limit.; 68.312 On-hook impedance limit.; 68.314 Billing protection

[12/T01b]
68.316 and 68.317 Hearing Aid Compatibility: technical standards

[12/T01c]
68.302 Environmental simulation (Par. a,b)

[12/TIA968] ANSI/TIA-968-A (2003)
Telephone Terminal Equipment, Technical Requirements for Connection of Terminal Equipment to the Telephone Network

[12/TIA968a] ANSI/TIA-968-A-1 (2003)
Telephone Terminal Equipment, Technical Requirements for Connection of Terminal Equipment to the Telephone Network - Addendum 1

[12/TIA968b] ANSI/TIA-968-A-2 (2004)
Telephone Terminal Equipment, Technical Requirements for Connection of Terminal Equipment to the Telephone Network - Addendum 2

[12/TIA968c] ANSI/TIA-968-A-3 (2005)
Telephone Terminal Equipment, Technical Requirements for Connection of Terminal Equipment to the Telephone Network - Addendum 3

Return to NVLAP Program Listing


Return to top of page NVLAP Home | Accredited Laboratories | Fields of Accreditation | Publications/Applications |
Mutual Recognition Arrangements | Assessor Resources | Contact NVLAP
Return to top of page

For questions concerning the National Voluntary Laboratory Accreditation Program, contact us:

National Voluntary Laboratory Accreditation Program, Standards Services Division, NIST, 100 Bureau Drive, Stop 2140, Gaithersburg, MD 20899-2140
Phone: (301) 975-4016, Fax: (301) 926-2884, Email: NVLAP@nist.gov

Date created: July 26, 2002
Last Updated: November 1, 2009

Privacy Statement / Security Notice / Accessibility Statement | Disclaimer | FOIA