Technology Services, National Voluntary Laboratory Accreditation Program, NIST Go to Technology Services Home Page Go to NIST Home Page Go to National Voluntary Laboratory Accreditation Program Home Page Go to Directory of Accredited Laboratories Go to Fields of Accreditation Go to Publications/Applications Go to Mutual Recognition Arrangements Go to Assessor Resources Contact National Voluntary Laboratory Accreditation Program

Universal Compliance Labs dba EMCE Engineering

NVLAP Lab Code: 200092-0


Address and Contact Information:

44366 South Grimmer Boulevard
Fremont, CA 94538-6385
Contact: Mr. Bob Cole
Phone: 510-490-4307
Fax: 510-490-3441
E-Mail: bob@universalcompliance.com
Send E-Mail to Laboratory: Universal Compliance Labs dba EMCE Eng.
URL: http://www.universalcompliance.com

NVLAP Accreditation Information

Listed below is the scope of accreditation for this laboratory as of November 1, 2009. For additional information, contact NVLAP at (301) 975-4016.

Send E-Mail to NVLAP at: NVLAP@nist.gov


Electromagnetic Compatibility & Telecommunications

Accreditation Valid From: January 1, 2009 Through: December 31, 2009

  • Emissions Test Methods

[12/160D21] RTCA/DO-160D (1997)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 21 - Emission of Radio Frequency Energy

[12/160F21] RTCA/DO-160F (2007)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 21 - Emissions of Radio Frequency Energy

[12/60F214] RTCA DO-160F
Section 21.4, RF Emissions, Conducted

[12/60F215] RTCA DO-160F
Section 21.5, RF Emissions, Radiated

[12/CIS11]
IEC/CISPR 11 + A1 (1997), EN 55011 (1998), AS/NZS CISPR 11 (2002), and CNS 13803 (1997): Limits and Methods of Measurement of Electromagnetic Disturbance Characteristics of Industrial, Scientific, and Medical Radio-Frequency Equipment

[12/CIS11a] IEC/CISPR 11, edition 3.1 (1999-08) & EN 55011 (1998)
Industrial, scientific and medical (ISM) radio-frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement

[12/CIS11b] IEC/CISPR 11(2003) & EN 55011(1998), A1(1999), A2(2002)
Industrial, scientific and medical (ISM) radio-frequency equipment - Radio disturbance characteristics - Limits and methods of measurement

[12/CIS11c] IEC/CISPR 11 (1997), A1 (1999), A2 (2002)
Industrial, Scientific and Medical (ISM) radio frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement

[12/CIS11d] EN 55011 (1998), A1 (1999), A2 (2002)
Industrial, Scientific and Medical (ISM) radio frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement

[12/CIS22] IEC/CISPR 22 (1997) & EN 55022 (1998) + A1(2000)
Limits and methods of measurement of radio disturbance characteristics of information technology equipment

[12/CIS22a] IEC/CISPR 22 (1993) and EN 55022 (1994)
Limits and methods of measurement of radio disturbance characteristics of information technology equipment, Amendment 1 (1995) and Amendment 2 (1996)

[12/CIS22b] CNS 13438 (1997)
Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment

[12/F18] FCC OST/MP-5 (1986)
FCC Methods of Measurement of Radio Noise Emissions for ISM Equipment (cited in FCC Method 47 CFR Part 18 - Industrial, Scientific, and Medical Equipment)

[12/FCC11] ANSI C63.4 (2003) with FCC Method - 47 CFR Part 11
Emergency Alert System (EAS)

[12/FCC15b] ANSI C63.4 (2003) with FCC Method 47 CFR Part 15, Subpart B
Unintentional Radiators

[12/FCC15b1] ANSI C63.4 (2003) with FCC Method 47 CFR Part 15, Subpart B
Unintentional Radiators

[12/FCC15c] ANSI C63.4 (2003) with FCC Method 47 CFR Part 15, Subpart C
Intentional Radiators

[12/ICES003] ICES-003 Issue 4 (2004)
Implementation and Interpretation of the Interference-Causing Equipment Standard for Digital Apparatus. (Industry Canada)

[12/T51a] AS/NZS CISPR 22 (2004)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

[12/VCCId] Agreement of VCCI V-3 (2008.04)
Agreement of Voluntary Control Council for Interference by Information Technology Equipment - Technical Requirements: V-3/2008.04

  • Immunity Test Methods

[12/I01] IEC 61000-4-2, Ed. 1.2 (2001) + A1, A2; EN 61000-4-2
Electrostatic Discharge Immunity Test

[12/I03] IEC 61000-4-4(1995), A1(2000), A2(2001); EN 61000-4-4
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical Fast Transient/Burst Immunity Test

[12/I04] IEC 61000-4-5, Ed. 1.1 (2001-04); EN 61000-4-5
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test

[12/I05] IEC 61000-4-6, Ed. 2.0 (2003-05); EN 61000-4-6
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields

[12/I07] IEC 61000-4-11, Ed. 1.1 (2001-03); EN 61000-4-11
Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests

[12/I08] IEC/CISPR 24 (1997), Amd1, A1(2001); EN 55024 (1998)
Information technology equipment - Immunity characteristics - Limits and methods of measurement

  • Radio Test Methods

[12/300220a] EN 300 220-1 V1.3.1 (2000-09)
Electromagnetic compatibility and Radio spectrum Matters; Short Range Devices; Radio equipment to be used in the 25 MHz to 1,000 MHz frequency range with power levels ranging up to 500 mW; Part 1: Technical characteristics and test methods

[12/300220b] ETSI EN 300 220-2 v1.3.1 (2000-09)
ERM; Short Range Devices; Radio equipment to be used in the 25 MHz to 1,000 MHz frequency range with power levels ranging up to 550 mW; Part 2: Supplementary parameters not intended for conformity purposes

[12/300328a] ETSI EN 300 328-1 V1.2.2 (2000-07)
ERM; Wideband Transmission systems; Data transmission equipment operating in the 2.4 GHz ISM band and using spread spectrum modulation techniques; Part 1: Technical characteristics and test conditions

[12/300328b] ETSI EN 300 328-2 v1.2.1 (2001-12)
Wideband Transmission systems; Data transmission equipment operating in the 2.4 GHz ISM band and using spread spectrum modulation techniques; Part 2: Harmonized EN covering essential requirements under article 3.2 of the R&TTE Directive

[12/300330a] ETSI EN 300 330-1 v1.3.2 (2002-12)
ERM; Short Range Devices; Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Part 1: Technical characteristics and test methods

[12/300440a] ETSI EN 300 440-1 v1.3.1 (2001-09)
Electromagnetic compatibility and Radio spectrum Matters (ERM): Short range devices; Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Part 1: Technical characteristics and test methods

[12/300440b] ETSI EN 300 440-2 v1.1.1 (2001-09)
Electromagnetic compatibility and Radio spectrum Matters (ERM); Short range devices; Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Part 2: Harmonized EN under article 3.2 of the R&TTE Directive

[12/301489a] ETSI EN 301 489-1 v1.5.1 (2004-11)
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements

[12/301489b] ETSI EN 301 489-3 v1.4.1 (2002-08)
Electromagnetic compatibility and Radio spectrum Matters; ElectroMagnetic Compatibility standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 40 GHz

[12/301489c] ETSI EN 301 489-4 v1.3.1 (2002-08)
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 4: Specific conditions for fixed radio links and ancillary equipment and services

[12/301489d] ETSI EN 301 489-5 v1.3.1 (2002-08)
Electromagnetic compatibility & Radio spectrum Matters (ERM); EMC standard for radio equipment and services; Part 5: Specific conditions for Private land Mobile Radio (PMR) and ancillary equipment (speech and non-speech)

[12/301489e] ETSI EN 301 489-6 v1.2.1 (2002-08)
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 6: Specific conditions for Digital Enhanced Cordless Telecommunications (DECT) equipment

[12/301489f] ETSI EN 301 489-7 v1.2.1 (2002-08)
ERM; EMC standard for radio equipment and services; Part 7: Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS)

[12/301489g] ETSI EN 301 489-8 v1.2.1 (2002-08)
ElectroMagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 8: Specific conditions for GSM base stations

[12/301489h] ETSI EN 301 489-9 v1.3.1 (2002-08)
ERM; EMC standard for radio equipment and services; Part 9: Specific conditions for wireless microphones, similar Radio Frequency (RF) audio link equipment, cordless audio and in-ear monitoring devices

[12/301489i] ETSI EN 301 489-10 v1.3.1 (2002-08)
EMR; ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 10: Specific conditions for First (CT1 and CT1+) and Second Generation Cordless Telephone (CT2) equipment

[12/301489j] ETSI EN 301 489-16 v1.2.1 (2002-08)
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility standard for radio equipment and services; Part 16: Specific conditions for analogue cellular radio communications equipment, mobile and portable

[12/301489k] ETSI EN 301 489-17 v1.1.1 (2000-09)
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for Wideband data and HIPERLAN equipment

[12/301489m] ETSI EN 301 489-17 v1.2.1 (2002-08)
Electromagnetic compatibility and Radio spectrum Matters (ERM); EMC standard for radio equipment and services; Part 17: Specific conditions for 2.4 GHz wideband transmission systems and 5 GHz high performance RLAN equipment

[12/301489n] ETSI EN 301 489-18 v1.3.1 (2002-08)
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 18: Specific conditions for Terrestrial Trunked Radio (TETRA) equipment

[12/301489o] ETSI EN 301 489-19 v1.2.1 (2002-11)
ERM; ElectroMagnetic Compatibility (EMC) standard for radiio equipment and services; Part 19: Specific conditions for Receive Only Mobile Earth Stations (ROMES) operating in the 1.5 GHz band providing data communications

[12/301489p] ETSI EN 301 489-20 v1.2.1 (2002-11)
Electromagnetic compatibility and Radio spectrum Matters; ElectroMagnetic Compatibility standard for radio equipment and services; Part 20: Specific conditions for Mobile Earth Stations (MES) used in the Mobile Satellite Services (MSS)

[12/301489q] ETSI EN 301 489-23 v1.2.1 (2002-11)
Electromagnetic compatibility and Radio spectrum Matters (ERM); EMC standard for radio equipment and services; Part 23: Specific conditions for IMT-2000 CDMA Direct Spread (Ultra) Base Station (BS) radio, repeater and ancillary equipment

[12/301489r] ETSI EN 301 489-24 v1.2.1 (2002-11)
Electromagnetic compatibility and Radio spectrum Matters (ERM); EMC standard for radio equipment and services; Part 24: Specific conditions for IMT-2000 CDMA Direct Spread (UTRA) for Mobile and portable (UE) radio and ancillary equipment

[12/301489s] ETSI EN 301 489-25 v2.2.1 (2003-05)
Electromagnetic compatibillity and Radio spectrum Matters (ERM); EMC standard for radio equipment and services; Part 25: Specific conditions for IMT-2000 CDMA Multi-carrier Mobile Stations and ancillary equipment

[12/301489t] ETSI EN 301 489-26 v2.2.1 (2003-05)
Electromagnetic compatibility and Radio spectrum Matters (ERM); EMC standard for radio equipment and services; Part 26: Specific conditions for IMT-2000 CDMA Multi-carrier Base Stations and ancillary equipment

[12/IDA48] IDA TS SRD, Issue 1, Rev. 1 (July 21, 2005)
Technical Specification for Short Range Devices

[12/LP0002a] LP0002 (January 2002)
Low-power Radio-frequency Devices, Technical Specifications - Sections: 3, 4.3, 4.4, 4.5, 4.6, and 4.7

[12/LP0002b] LP0002 (2003)
Low-power Radio-frequency Devices - Technical Regulations

[12/RSS111] RSS-111 Issue 1 (July 2006)
Broadband Public Safety Equipment

[12/RSS117] RSS-117, Issue 2 (March 30, 1974)
Land and Coast Station Transmitters Using A1, A2, A3, A2H or A3H Emissions Operating in the 200 - 535 kHz Band

[12/RSS210] RSS-210, Issue 6 (Sept. 2005)
Low Power Licence-Exempt Radiocommunication Devices (All Frequency Bands): Category 1 Equipment

[12/RSS212] RSS-212, Issue 1 (February 27, 1999)
Test Facilities and Test Methods for Radio Equipment

[12/RSS213a] RSS-213 Issue 2 (December 2005)
2 GHz Licence-Exempt Personal Communications Service Devices (PCS)

Return to NVLAP Program Listing


Return to top of page NVLAP Home | Accredited Laboratories | Fields of Accreditation | Publications/Applications |
Mutual Recognition Arrangements | Assessor Resources | Contact NVLAP
Return to top of page

For questions concerning the National Voluntary Laboratory Accreditation Program, contact us:

National Voluntary Laboratory Accreditation Program, Standards Services Division, NIST, 100 Bureau Drive, Stop 2140, Gaithersburg, MD 20899-2140
Phone: (301) 975-4016, Fax: (301) 926-2884, Email: NVLAP@nist.gov

Date created: July 26, 2002
Last Updated: November 1, 2009

Privacy Statement / Security Notice / Accessibility Statement | Disclaimer | FOIA