3M Product Safety EMC Laboratory

NVLAP Lab Code: 200033-0


Address and Contact Information:

410 Fillmore Avenue East
Bldg 76-1-01
St. Paul, MN 55107-1248
Contact: Mr. Steven D Wytaske
Phone: 651-778-4577
Fax: 651-778-6252
E-Mail: sdwytaske1@mmm.com
Send E-Mail to Laboratory: 3M Product Safety EMC Laboratory

NVLAP Accreditation Information

Listed below is the scope of accreditation for this laboratory as of February 10, 2012. For additional information, contact NVLAP at (301) 975-4016.

Send E-Mail to NVLAP at: NVLAP@nist.gov


Electromagnetic Compatibility & Telecommunications

Accreditation Valid From: July 1, 2011 Through: June 30, 2012

  • Emissions Test Methods

[12/610006p] IEC 61000-6-3 (2006-06)
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments

[12/61000g] EN 61000-6-3 (2007)
Electromagnetic compatibility (EMC) - Part 6-3: Generic standard - Emission standard for residential, commericial and light industrial environments

[12/CIS11jj] EN 55011 (2007) + A2 (2007)
Industrial, scientific and medical (ISM) radio-frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement

[12/CIS14a4] EN 55014-1 (2006)
Electromagnetic Compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission

[12/CIS14x1] IEC/CISPR 14-1, Ed. 5.0 (2005)
Electromagnetic Compatibility - Requirements for Household Appliances, Electric Tools and Similar Apparatus - Part 1: Emission

[12/CIS22L] EN 55022 (2006) + A1 (2007)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

[12/CIS22j] EN 55022 (2006)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

[12/CIS22k] IEC/CISPR 22 (2008-09)
Limits and Methods of Measurement of Radio Disturbance Characteristics of Information Technology Equipment

[12/EM02i] IEC 61000-3-2, Ed. 3.0 (2005-11)
Electromagnetic compatability (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <=16 A per phase)

[12/EM02j] EN 61000-3-2 (2006)
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase)

[12/EM03m] EN 61000-3-3, Ed. 2.0 (2008-09)
EMC- Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low- voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection

[12/EM12] IEC 61000-3-12, Rev 04, November 2004
Electromagnetic Compatibility (EMC) - PART 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current greater than 16 A and less than or equal to 75 A

[12/EN11] EN 61000-3-11, Rev 01, Feb 2001
Electromagnetic Compatibility (EMC) Limits, Limitation of Voltage Changes, Voltage Fluctuations and Flicker in public low-voltage supply systems - Equipment with rated voltage current < 75 A and subject to conditional connection

[12/F18] FCC OST/MP-5 (1986)
FCC Methods of Measurement of Radio Noise Emissions for ISM Equipment (cited in FCC Method 47 CFR Part 18 - Industrial, Scientific, and Medical Equipment)

[12/FCC15b] ANSI C63.4 (2003) with FCC Method 47 CFR Part 15, Subpart B
Unintentional Radiators

[12/FCC15c2] DA 00-705 - March 30, 2000 and KDB Pub. No. 558074
with FCC Method - 47 CFR Part 15, Subpart C: Intentional Radiators - (Filing and Measurement Guidelines for Frequency Hopping Spread Spectrum Systems - and - New Guidance on Measurements for Digital Transmission Systems in Section 15.247)

[12/KN11d] KN11 (2008-5) with RRL Notice No. 2008-3 (May 20, 2008)
Conformity Assessment Procedure for Electromagnetic Interference; With KN 11

[12/KN22e] KN22 (2008-5) with RRL Notice No. 2008-3 (May 20, 2008)
Conformity Assessment Procedure for Electromagnetic Interference; With KN 22

[12/T51b] AS/NZS CISPR 22, 3rd Edition (2006)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

  • Immunity Test Methods

[12/610006j] EN 61000-6-2 (2005)
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments

[12/610006n] EN 61000-4-4 (2007)
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical Fast Transient/Burst Immunity Test

[12/61000k] EN 61000-6-1 (2007)
Electromagnetic compatibility (EMC) - Part 6 - 1: Generic standards - Immunity for residential, commercial and light-industrial environments

[12/I01d] IEC 61000-4-2, Ed. 2.0 (2008-12)
Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test

[12/I02gg] IEC 61000-4-3, Ed. 3.0 (2006-02) + A1 (2007)
Electromagnetic compatibility (EMC) - Part 4-3: Testing measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

[12/I02hh] EN 61000-4-3 (2006) +A1 (2008)
Electromagnetic compatibility (EMC). Testing and measurement techniques. Radiated, radio- Frequency, electromagnetic field immunity test

[12/I03e] EN 61000-4-4 (2004)
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test

[12/I04aa] IEC 61000-4-5, Ed. 2.0 (2005-11); EN 61000-4-5
Electromagnetic Compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test

[12/I04d] BS EN 61000-4-5 (2006)

[12/I05cc] IEC 61000-4-6 (2003-05) + A2 (2006-03)
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields

[12/I05h] EN 61000-4-6 (2007)
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields

[12/I06c] EN 61000-4-8 (1993) + A1 (2001)
Power Frequency Magnetic Field Immunity Test

[12/I07f] EN 61000-4-11 (2004)
Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests

[12/I07g] IEC 61000-4-11 (2004)
Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests

[12/IEC407] IEC 61000-4-7, Ed 2.0 (2002-08)
Immunity to conducted disturbances

[12/KN11f] KN 61000-4-11 (2008-5); RRL Notice No. 2008-4 (May 20, 2008)
Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests

[12/KN150] EMS RRL Notice No. 2005-130: 2005.12.27
RRL Notice No. 2005-130: Technical Requirements for Electromagnetic Susceptibility Annex 1-7 (KN61000-4-2, -3, -4, -5, -6, -8, -11), RRL Notice No. 2005-132: Conformity Assessment Procedures for Electromagnetic Susceptibility

[12/KN24d] KN 24 (2008-5) with RRL Notice No. 2008-4 (May 20, 2008)
Information Technology Equipment - immunity charateristics - limits and methods of measurements

[12/KN2a] KN 61000-4-2 with RRL Notice No. 2005-130 (Dec. 27, 2005)
Electrostatic Discharge Immunity Test

[12/KN2b] KN 61000-4-2 (Annex 1);RRL Notice No. 2007-101(Dec. 26 2007)
Electrostatic Discharge Immunity Test

[12/KN3c] KN 61000-4-3 (2008-5); RRL Notice No. 2008-4 (May 20, 2008)
Radiated, radio-frequency, electromagnetic field immunity test

[12/KN4c] KN 61000-4-4 (2008-5); RRL Notice No. 2008-5 (May 20, 2008)
Electromagnetic compatibility (EMC): Testing and measurement techniques - Electrical Fast Transient/Burst Immunity Test

[12/KN5c] KN 61000-4-5 (2008-5); RRL Notice No. 2008-4 (May 20, 2008)
Surge Immunity Test

[12/KN6c] KN 61000-4-6 (2008-5); RRL Notice No. 2008-4 (May 20, 2008)
Electromagnetic compatibility (EMC): Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields

[12/KN8c] KN 61000-4-8 (2008-5); RRL Notice No. 2008-4 (May 20, 2008)
Power Frequency Magnetic Field Immunity Test

  • Product Safety Test Methods

[12/60601h] EN 60601-1-2 (2001)
Medical electrical equipment - Part 1 and Part 1-2: General requirements for safety: Collateral standard: EMC - Requirements and tests

  • RF Exposure Test Methods

[12/50357] EN 50357:2001
Evaluation of Human Exposure to EM Fields from Devices used in Electronic Article Surveillance

[12/C95b] IEEE C95.1 -1999
IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3kHz to 300 GHz

  • Radio Test Methods

[12/300220d] ETSI EN 300 220-1 V2.1.1 (2006-04)
Electromagnetic Compatibility Radio Spectrum Matters; Short Range Devices; Radio Equipment to be used in the 25 MHz to 1,000 MHz Frequency Range with Power Levels Ranging up to 500mW; Part 1: Technical Characteristics and Test Methods

[12/300220f] ETSI EN 300 220-2 V2.1.2 (2007-06)
ERM; Short Range Devices; Radio Equipment to be used in the 25MHz to 1,000 MHz Frequency Range with Power Levels Ranging up to 550 mW; Part 2: Supplementary Parameters Not Intended for Conformity Purposes

[12/300330d] ETSI EN 300 330-2 V1.3.1 (2006-04)
ERM; Short Range Devices (SRD); Radio Equipment in the Frequency Range 9kHz to 30 MHz; Part 2: Harmonized EN Under Article 3.2 of the R&TTE Directive

[12/301489z] ETSI EN 301 489-1 v1.6.1 (2005-09)
ERM; ElectroMagnetic Compatability (EMC) Standard for Radio Equipment and Services; Common Technical Requirements

[12/322912] EN 302 291-2, v1.1.1
ERM; Short Range Devices; Close Range Inductive Data Communication equipment operating at 13,56 MHz - Part 2: Harmonized EN covering essential requirements of Article 3(2) of the R&TTE Directive

Return to NVLAP Program Listing