PCTEST Engineering Laboratory, Inc.NVLAP Lab Code: 100431-0
Address and Contact Information:
6660-B Dobbin Road
Columbia, MD 21045-4844
Contact: Mr. Randy Ortanez
Phone: 410-290-6652
Fax: 410-290-6654
E-Mail: randy@pctestlab.com
Send E-Mail to Laboratory: PCTEST Engineering Laboratory, Inc.
URL: http://www.pctestlab.com
NVLAP Accreditation Information
Listed below is the scope of accreditation for this laboratory as of November 1, 2009. For additional information, contact NVLAP at (301) 975-4016.
Send E-Mail to NVLAP at: NVLAP@nist.gov
Electromagnetic Compatibility & Telecommunications
Accreditation Valid From: October 1, 2009 Through: September 30, 2010
[12/CIS22] IEC/CISPR 22 (1997) & EN 55022 (1998) + A1(2000)
Limits and methods of measurement of radio disturbance characteristics of information technology equipment
[12/CIS22a] IEC/CISPR 22 (1993) and EN 55022 (1994)
Limits and methods of measurement of radio disturbance characteristics of information technology equipment, Amendment 1 (1995) and Amendment 2 (1996)
[12/CIS22b] CNS 13438 (1997)
Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment
[12/FCC15b] ANSI C63.4 (2003) with FCC Method 47 CFR Part 15, Subpart B
Unintentional Radiators
[12/FCC15c] ANSI C63.4 (2003) with FCC Method 47 CFR Part 15, Subpart C
Intentional Radiators
[12/ICES003] ICES-003 Issue 4 (2004)
Implementation and Interpretation of the Interference-Causing Equipment Standard for Digital Apparatus. (Industry Canada)
[12/T51a] AS/NZS CISPR 22 (2004)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
[12/VCCIa] VCCI
Agreement of Voluntary Control Council for Interference by Information Technology Equipment - Technical Requirements: V-3/2005.04
[12/I01] IEC 61000-4-2, Ed. 1.2 (2001); EN 61000-4-2
Electrostatic Discharge Immunity Test
[12/I02] IEC 61000-4-3, Ed. 2.0 (2002-03); EN 61000-4-3 (2002)
Radiated Radio-Frequency Electromagnetic Field Immunity Test
[12/I03] IEC 61000-4-4(1995), A1(2000), A2(2001); EN 61000-4-4
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical Fast Transient/Burst Immunity Test
[12/I04] IEC 61000-4-5, Ed. 1.1 (2001-04); EN 61000-4-5
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
[12/I05] IEC 61000-4-6, Ed. 2.0 (2003-05); EN 61000-4-6
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
[12/I06] IEC 61000-4-8, Ed. 1.1 (2001); EN 61000-4-8
Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
[12/I07] IEC 61000-4-11, Ed. 1.1 (2001-03); EN 61000-4-11
Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests
[12/KN11] KN 61000-4-11 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests
[12/KN2] KN 61000-4-2 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Electrostatic Discharge Immunity Test
[12/KN3] KN 61000-4-3 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Radiated, radio-frequency, electromagnetic field immunity test
[12/KN4] KN 61000-4-4 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Electromagnetic compatibility (EMC): Testing and measurement techniques - Electrical Fast Transient/Burst Immunity Test
[12/KN5] KN 61000-4-5 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Surge Immunity Test
[12/KN6] KN 61000-4-6 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Electromagnetic compatibility (EMC): Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
[12/KN8] KN 61000-4-8 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Power Frequency Magnetic Field Immunity Test
[12/300220b] ETSI EN 300 220-2 v1.3.1 (2000-09)
ERM; Short Range Devices; Radio equipment to be used in the 25 MHz to 1,000 MHz frequency range with power levels ranging up to 550 mW; Part 2: Supplementary parameters not intended for conformity purposes
[12/300328f] ETSI EN 300 328 V1.6.1 (2004-07)
ERM; Wideband Transmission systems; Data transmission equipment operating in the 2.4 GHz ISM band and using wide band modulation techniques; Harmonized EN covering essential requirements under article 3.2 of the R&TTE Directive
[12/300330b] ETSI EN 300 330-2 v1.1.1 (2001-06)
ERM; Short Range Devices (SRD); Radio equipment in the frequency range 9kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Part 2: Harmonized EN under article 3.2 of the R&TTE Directive
[12/301489a] ETSI EN 301 489-1 v1.5.1 (2004-11)
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements
[12/301489b] ETSI EN 301 489-3 v1.4.1 (2002-08)
Electromagnetic compatibility and Radio spectrum Matters; ElectroMagnetic Compatibility standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 40 GHz
[12/301489f] ETSI EN 301 489-7 v1.2.1 (2002-08)
ERM; EMC standard for radio equipment and services; Part 7: Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS)
Return to NVLAP Program Listing
NVLAP Home |
Accredited Laboratories |
Fields of Accreditation |
Publications/Applications |
Mutual Recognition Arrangements |
Assessor Resources |
Contact NVLAP 
For questions concerning the National Voluntary Laboratory Accreditation Program, contact us:
National Voluntary Laboratory Accreditation Program, Standards Services Division, NIST, 100 Bureau Drive, Stop 2140, Gaithersburg, MD 20899-2140
Phone: (301) 975-4016, Fax: (301) 926-2884, Email: NVLAP@nist.gov
Date created: July 26, 2002
Last Updated: November 1, 2009
Privacy
Statement / Security Notice / Accessibility Statement | Disclaimer
| FOIA
|