PCTEST Engineering Laboratory, Inc.

NVLAP Lab Code: 100431-0


Address and Contact Information:

6660-B Dobbin Road
Columbia, MD 21045-4844
Contact: Mr. Randy Ortanez
Phone: 410-290-6652
Fax: 410-290-6654
E-Mail: randy@pctestlab.com
Send E-Mail to Laboratory: PCTEST Engineering Laboratory, Inc.
URL: http://www.pctestlab.com

NVLAP Accreditation Information

Listed below is the scope of accreditation for this laboratory as of November 14, 2014. For additional information, contact NVLAP at (301) 975-4016.

Send E-Mail to NVLAP at: NVLAP@nist.gov


Electromagnetic Compatibility & Telecommunications

Accreditation Valid From: October 1, 2014 Through: September 30, 2015

  • Emissions Test Methods

[12/C6310] ANSI C63.10-2009
American National Standard for Testing Unlicensed Wireless Devices

[12/CIS11h2] AS/NZS CISPR 11 (2011)
Industrial, scientific and medical (ISM) radio frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement

[12/CIS11m2] EN 55011 (2009) + A1 (2010)
Industrial, scientific and medical (ISM) radio-frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement

[12/CIS11pp] IEC/CISPR 11 Ed 5 (2009-05) + A1 (2010)
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement

[12/CIS22c3] IEC/CISPR 22, Edition 5 (2005) + A1(2005)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

[12/CIS22f] CNS 13438 (2006) (up to 6GHz)
LImits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment

[12/CIS22j1] EN 55022 (2006) + A1 (2007)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

[12/EM02ii] IEC 61000-3-2, Ed. 3.0 (2005) +A1 (2008) +A2 (2009)
Electromagnetic compatability (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <=16 A per phase)

[12/EM02ii1] EN 61000-3-2:2006 + A1:2009 + A2:2009
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <=16 A per phase)

[12/EM03n] IEC 61000-3-3 Ed. 2.0 (2008)
EMC- Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current =16 A per phase and not subject to conditional connection

[12/FCC15b] ANSI C63.4 (2003) with FCC Method 47 CFR Part 15, Subpart B
Unintentional Radiators

[12/FCC15bb] ANSI C63.4 (2009) with FCC Method 47 CFR Part 15, Subpart B
Unintentional Radiators

[12/FCC15c] ANSI C63.4 (2003) with FCC Method 47 CFR Part 15, Subpart C
Intentional Radiators

[12/FCC15cc] ANSI C63.4 (2009) with FCC Method 47 CFR Part 15, Subpart C
Intentional Radiators

[12/FCC15e2] ANSI C63.4 (2003) with FCC Method 47 CFR Part 15, Subpart E
Unlicensed National Information Infrastructure Service Devices (Limited to TX conducted and radiated power and RX-TX radiated spurious emissions)

[12/FCC15e4] ANSI C63.4 (2009) with FCC Method 47 CFR Part 15, Subpart E
Unlicensed National Information Infrastructure Service Devices (Limited to TX conducted and radiated power and RX-TX radiated spurious emissions)

[12/ICES03a] ICES-003 Issue 5 (2012)
Information Technology Equipment (ITE) Limits and methods of measurement

[12/KN22] KN22 with RRL Notice No. 2005-82 (Sept. 29, 2005)
RRL Notice No. 2005-82: Technical Requirements for Electromagnetic Interference Annex 8 (KN-22), RRL Notice No. 2005-131: Conformity Assessment Procedures for Electromagnetic Interference

[12/KNcis11] KN11 with RRL Notice No. 2005-82 (Sept. 29, 2005)
Industrial, scientific and medical (ISM) radio frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement

[12/T51b1] AS/NZS CISPR 22 (2009)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

  • Immunity Test Methods

[12/CIS24] IEC/CISPR 24 (1997) A2(2002) & EN 55024 (1998) A2(2003)
Information technology equipment - Immunity characteristics - Limits and methods of measurement

[12/CIS24g] CISPR 24 ed2.0 (2010-08)
Information technology equipment - Immunity characteristics - Limits and methods of measurement

[12/CIS24h] EN 55024 (2010)
Information technology equipment. Immunity characteristics. Limits and methods of measurement

[12/I01d] IEC 61000-4-2, Ed. 2.0 (2008-12)
Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test

[12/I01f] EN 61000-4-2 (2009-05)
Electromagnetic compatibility (EMC) - Part 4-2 : Testing and measurement techniques - Electrostatic discharge immunity test

[12/I02hh1] EN 61000-4-3 (2006) + A2 (2010)
Electromagnetic compatibility (EMC). Testing and measurement techniques. Radiated, radio- Frequency, electromagnetic field immunity test

[12/I02i] IEC 61000-4-3, Ed. 3.1 (2008-04)
Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

[12/I03e2] EN 61000-4-4:2012
Electromagnetic compatibility (EMC). Testing and measurement techniques. Electrical fast transient/burst immunity test

[12/I03i] IEC 61000-4-4 (2012-04)
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test

[12/I04c1] IEC 61000-4-5, Ed 2 (2005-11)
EMC - Part 4-5: Testing and measurement techniques - Surge immunity test

[12/I04d] BS EN 61000-4-5 (2006)
Electromagnetic compatibility (EMC). Testing and measurement techniques. Surge immunity test

[12/I05f2] IEC 61000-4-6 ed4.0 (2013)
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields

[12/I05p] EN 61000-4-6 (2014)
Electromagnetic compatibility (EMC). Testing and measurement techniques. Immunity to conducted disturbances, induced by radio-frequency fields

[12/I06e] IEC 61000-4-8 (2009)
Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test

[12/I06f] EN 61000-4-8:2010
Electromagnetic compatibility (EMC). Testing and measurement techniques. Power frequency magnetic field immunity test

[12/I07f] EN 61000-4-11 (2004)
Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests

[12/I07g] IEC 61000-4-11 (2004)
Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests

[12/KN11] KN 61000-4-11 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests

[12/KN2] KN 61000-4-2 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Electrostatic Discharge Immunity Test

[12/KN3] KN 61000-4-3 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Radiated, radio-frequency, electromagnetic field immunity test

[12/KN4] KN 61000-4-4 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Electromagnetic compatibility (EMC): Testing and measurement techniques - Electrical Fast Transient/Burst Immunity Test

[12/KN5] KN 61000-4-5 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Surge Immunity Test

[12/KN6] KN 61000-4-6 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Electromagnetic compatibility (EMC): Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields

[12/KN8] KN 61000-4-8 with RRL Notice No. 2005-83 (Sept. 29, 2005)
Power Frequency Magnetic Field Immunity Test

[12/PC69a] ANSI/AAMI PC69:2007; (Sections 4.8 and 4.9 only)
Active implantable medical devices - Electromagnetic compatibility: EMC test Protocols for Implatable cardiac pacemakers and implantable cardioverter devibrillators

  • Product Safety Test Methods

[12/60601ab] IEC 60601-1-2, Ed. 3.0 (2007)
Medical electrical equipment - Part 1-2: General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and tests

  • Radio Test Methods

[12/300220b] ETSI EN 300 220-2 v1.3.1 (2000-09)
ERM; Short Range Devices; Radio equipment to be used in the 25 MHz to 1,000 MHz frequency range with power levels ranging up to 550 mW; Part 2: Supplementary parameters not intended for conformity purposes

[12/300220j] ETSI EN 300 220-1 V2.4.1 (2012-05)
(ERM); Short Range Devices (SRD); Radio equipment to be used in the 25 MHz to 1 000 MHz frequency range with power levels ranging up to 500 mW; Part 1: Technical characteristics and test methods

[12/300328g] ETSI EN 300 328 V1.7.1 (2006-10)
ERM; Wideband Transmission Systems; Data transport equipment operating in the 2.4 GHz ISM band and using wide band modulation techniques; Harmonized EN covering essential requirements under article 3.2 of the R&TTE Directive

[12/300328i] ETSI EN 300 328 V1.8.1 (2012-06)
ERM; Wideband Transmission Systems; Data transport equipment operating in the 2.4 GHz ISM band and using wide band modulation techniques; Harmonized EN covering essential requirements under article 3.2 of the R&TTE Directive

[12/300330e] ETSI EN 300 330-2 V1.5.1 (2010-02)
ERM; Short Range Devices (SRD); Radio Equipment in the Frequency Range 9kHz to 30 MHz; Part 2: Harmonized EN Under Article 3.2 of the R&TTE Directive

[12/300330f] ETSI EN 300 330-1 V1.7.1 (2010-02)
ERM; Short Range Devices; Radio Equipment in the Frequency Range 9kHz to 25 MHz and Inductive Loop Systems in the Frequency Range 9kHz to 30 MHz; Part 1: Technical Characteristics and Test Methods

[12/300440h] ETSI EN 300 440-1 V1.6.1 (2010-08)
Electromagnetic compatibility and Radio spectrum Matters (ERM): Short range devices; Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Part 1: Technical characteristics and test methods

[12/300440i] ETSI EN 300 440-2 v1.4.1 (2010-08)
Electromagnetic compatibility and Radio spectrum Matters (ERM); Short range devices; Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Part 2: Harmonized EN under article 3.2 of the R&TTE Directive

[12/301489b] ETSI EN 301 489-3 v1.4.1 (2002-08)
Electromagnetic compatibility and Radio spectrum Matters; ElectroMagnetic Compatibility standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 40 GHz

[12/301839e] ETSI EN 301 839-1 V1.3.1 (2009-10)
ERM; Radio equipment in the frequency range 402 MHz to 405 MHz for Ultra Low Power Active Medical Implants and Accessories; Part 2: Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive

[12/301839f] ETSI EN 301 839-2 v1.3.1
ERM; Radio equipment in the frequency range 402 MHz to 405 MHz for Ultra Low Power Active Medical Implants and Accessories; Part 2: Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive

[12/301893e] ETSI EN 301 893 V1.6.1 (2011-11)
Broadband Radio Access Networks (BRAN); 5 GHz high performance RLAN; Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive

[12/301893f] ETSI EN 301 893 V1.7.1 (2012-06)
Broadband Radio Access Networks (BRAN); 5 GHz high performance RLAN; Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive

[12/302510] ETSI EN 302 510-1 V1.1.1
ERM; Radio equipment in the frequency range 30 MHz to 37,5 MHz for Ultra Low Power Active Medical Membrane Implants and Accessories; Part 1: Technical characteristics and test methods

[12/302510a] ETSI EN 302 510-2 V1.1.1
ERM, Radio equipment in the frequency range 30 MHz to 37,5 MHz for Ultra Low Power Active Medical Membrane Implants and Accessories, Part 1: Technical characteristics and test methods

[12/302537] ETSI EN 302 537-1 V1.1.2
ERM; Short Range Devices (SRD); Ultra Low Power Medical Data Service Systems operating in the frequency range 401 MHz to 402 MHz and 405 MHz to 406 MHz; Part 1: Technical characteristics and test methods

[12/302537a] ETSI EN 302 537-2 V1.1.2
ERM; Short Range Devices (SRD); Ultra Low Power Medical Data Service Systems operating in the frequency range 401 MHz to 402 MHz and 405 MHz to 406 MHz; Part 1: Technical characteristics and test methods

[12/31489ad] ETSI EN 301 489-1 V1.9.2 (2011-09)
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements

[12/31489fa] ETSI EN 301 489-7 v1.3.1 (2005-11)
ERM; EMC standard for radio equipment and services; Part 7: Specific conditions for moble and portable radio and ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS)

[12/31489m2] ETSI EN 301 489-17 V2.2.1 (2012-09)
(ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment; Part 17: Specific conditions for Broadband Data Transmission Systems

[12/31489z1] ETSI EN 301 489-34 V1.3.1 (2013-05)
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 34: Specific conditions for External Power Supply (EPS) for mobile phones

[12/322911] EN 302 291-1 V. 1.1.1
Electromagnetic compatibility and Radio spectrum Matters (ERM);Short Range Devices (SRD);Close Range Inductive Data Communication equipment operating at 13,56 MHz;Part 1: Technical characteristics and test methods

[12/322912] EN 302 291-2, v1.1.1
ERM; Short Range Devices; Close Range Inductive Data Communication equipment operating at 13,56 MHz - Part 2: Harmonized EN covering essential requirements of Article 3(2) of the R&TTE Directive

[12/48927] ETSI EN 301 489-27 V1.1.1 (2004-06)
ERM; EMC standard for radio equipment and services; Part 27: Specific conditions for Ultra Low Power Active Medical Implants (ULP-AMI) and related peripheal devices (ULP-AMI-P)

[12/LP0002c] DGT LP0002 (revised 24 March 2005)
DGT Low-power Radio-Frequency Devices Technical Regulations, LP0002 (revised 24 March 2005)

  • Site-Specific Information

[12/100431] 3m Chambers
Chamber #1 and #2 located at 7185 Oakland Mills Road, Columbia MD 21046

  • Telecommunications Test Methods

[12/300386c] EN 300 386 V1.3.2 (2003-05)
Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirements

Return to NVLAP Program Listing