Technology Services, National Voluntary Laboratory Accreditation Program, NIST Go to Technology Services Home Page Go to NIST Home Page Go to National Voluntary Laboratory Accreditation Program Home Page Go to Directory of Accredited Laboratories Go to Fields of Accreditation Go to Publications/Applications Go to Mutual Recognition Arrangements Go to Assessor Resources Contact National Voluntary Laboratory Accreditation Program

General Dynamics C4 Systems EMC Laboratory

NVLAP Lab Code: 100405-0


Address and Contact Information:

8201 E. McDowell Road
Mail Stop H2550
Scottsdale, AZ 85257
Contact: Mr. Harry Gaul
Phone: 480-441-5321
Fax: 480-441-3625
E-Mail: harry.gaul@gdc4s.com
Send E-Mail to Laboratory: General Dynamics C4 Systems EMC Lab

NVLAP Accreditation Information

Listed below is the scope of accreditation for this laboratory as of November 1, 2009. For additional information, contact NVLAP at (301) 975-4016.

Send E-Mail to NVLAP at: NVLAP@nist.gov


Electromagnetic Compatibility & Telecommunications

Accreditation Valid From: October 1, 2009 Through: September 30, 2010

  • Emissions Test Methods

[12/1399-30] MIL-STD 1399 Section 300A
Interface standard for Shipboard Systems: Electric Power, Alternating Current

[12/331B] MIL-STD-331B
Fuse and Fuse Components, Environmental and Performance Test for

[12/7637-1] ISO 7637-1, First edition (1990)
Road vehicles - Electrical disturbances from conduction and coupling - Part 1: Passenger cars and light commercial vehicles with nominal 12 V supply voltage - Electrical transient conduction along supply lines only

[12/7637-2] ISO 7637-2, First edition (1990)
Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Commercial vehicles with nominal 24 V supply voltage - Electrical transient conduction along supply lines only

[12/CIS11]
IEC/CISPR 11 + A1 (1997), EN 55011 (1998), AS/NZS CISPR 11 (2002), and CNS 13803 (1997): Limits and Methods of Measurement of Electromagnetic Disturbance Characteristics of Industrial, Scientific, and Medical Radio-Frequency Equipment

[12/CIS22] IEC/CISPR 22 (1997) & EN 55022 (1998) + A1(2000)
Limits and methods of measurement of radio disturbance characteristics of information technology equipment

[12/CIS22a] IEC/CISPR 22 (1993) and EN 55022 (1994)
Limits and methods of measurement of radio disturbance characteristics of information technology equipment, Amendment 1 (1995) and Amendment 2 (1996)

[12/CIS22b] CNS 13438 (1997)
Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment

[12/EM02a]
IEC 61000-3-2, Edition 2.1 (2001-10), EN 61000-3-2 (2000), and AS/NZS 2279.1 (2000): Electromagnetic compatibility (EMC) Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <= 16 A)

[12/EM02b] IEC 61000-3-2, Second Edition (2000-08)
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current<= 16 A per phase)

[12/EM02c] BS EN 61000-3-2, Ed. 2 (2001); IEC 61000-3-2, Ed. 2 (2000)
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase)

[12/EM03a] IEC 1000-3-3 (1994-12)

[12/EM03b] IEC 61000-3-3, Edition 1.1(2002-03) & EN 61000-3-3, A1(2001)
EMC - Part 3-3: Limits - Limitations of voltage changes, voltage flucuations and flicker, in public low-voltage supply-systems, for equipment with rated current <=16 A per phase and not subject to conditional connections

[12/EM03c] IEC/EN 61000-3-3 (1994) with Amendment 1 (2001)
Conducted Emissions, Voltage Flicker

[12/FCC15b] ANSI C63.4 (2003) with FCC Method 47 CFR Part 15, Subpart B
Unintentional Radiators

[12/T51a] AS/NZS CISPR 22 (2004)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

  • Immunity Test Methods

[12/I01] IEC 61000-4-2, Ed. 1.2 (2001); EN 61000-4-2
Electrostatic Discharge Immunity Test

[12/I02] IEC 61000-4-3, Ed. 2.0 (2002-03); EN 61000-4-3 (2002)
Radiated Radio-Frequency Electromagnetic Field Immunity Test

[12/I03] IEC 61000-4-4(1995), A1(2000), A2(2001); EN 61000-4-4
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical Fast Transient/Burst Immunity Test

[12/I04] IEC 61000-4-5, Ed. 1.1 (2001-04); EN 61000-4-5
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test

[12/I05] IEC 61000-4-6, Ed. 2.0 (2003-05); EN 61000-4-6
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields

[12/I06] IEC 61000-4-8, Ed. 1.1 (2001); EN 61000-4-8
Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test

[12/I07] IEC 61000-4-11, Ed. 1.1 (2001-03); EN 61000-4-11
Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests

  • MIL-STD-462 : Conducted Emissions

[12/A01]
MIL-STD-462 Method CE01

[12/A04]
MIL-STD-462 Method CE02

[12/A06]
MIL-STD-462 Method CE03

[12/A08]
MIL-STD-462 Method CE04

[12/A10]
MIL-STD-462 Method CE06

[12/A12]
MIL-STD-462 Method CE07

[12/A13]
MIL-STD-462 Version D Method CE101

[12/A14]
MIL-STD-462 Version D Method CE102

[12/A15]
MIL-STD-462 Version D Method CE106

[12/A16]
MIL-STD-461 Version E Method CE101

[12/A17]
MIL-STD-461 Version E Method CE102

[12/A18]
MIL-STD-461 Version E Method CE106

  • MIL-STD-462 : Conducted Susceptibility

[12/B01]
MIL-STD-462 Method CS01

[12/B02]
MIL-STD-462 Method CS02

[12/B04]
MIL-STD-462 Method CS03/CS04/CS05/CS08

[12/B05]
MIL-STD-462 Method CS06

[12/B06]
MIL-STD-462 Method CS07

[12/B07]
MIL-STD-462 Method CS09

[12/B08]
MIL-STD-462 Method CS10

[12/B09]
MIL-STD-462 Method CS11

[12/B10]
MIL-STD-462 Method CS12

[12/B11]
MIL-STD-462 Method CS13

[12/B12]
MIL-STD-462 Version D Method CS101

[12/B13]
MIL-STD-462 Version D Method CS103

[12/B14]
MIL-STD-462 Version D Method CS104

[12/B15]
MIL-STD-462 Version D Method CS105

[12/B16]
MIL-STD-462 Version D Method CS109

[12/B17]
MIL-STD-462 Version D Method CS114

[12/B18]
MIL-STD-462 Version D Method CS115

[12/B19]
MIL-STD-462 Version D Method CS116

[12/B20]
MIL-STD-461 Version E Method CS101

[12/B21]
MIL-STD-461 Version E Method CS103

[12/B22]
MIL-STD-461 Version E Method CS104

[12/B23]
MIL-STD-461 Version E Method CS105

[12/B24]
MIL-STD-461 Version E Method CS109

[12/B25]
MIL-STD-461 Version E Method CS114

[12/B26]
MIL-STD-461 Version E Method CS115

[12/B27]
MIL-STD-461 Version E Method CS116

  • MIL-STD-462 : Radiated Emissions

[12/D01]
MIL-STD-462 Method RE01

[12/D02]
MIL-STD-462 Method RE02

[12/D03]
MIL-STD-462 Method RE03

[12/D04]
MIL-STD-462 Version D Method RE101

[12/D05]
MIL-STD-462 Version D Method RE102

[12/D06]
MIL-STD-462 Version D Method RE103

[12/D07]
MIL-STD-461 Version E Method RE101

[12/D08]
MIL-STD-461 Version E Method RE102

[12/D09]
MIL-STD-461 Version E Method RE103

  • MIL-STD-462 : Radiated Susceptibility

[12/E01]
MIL-STD-462 Method RS01

[12/E02]
MIL-STD-462 Method RS02

[12/E03]
MIL-STD-462 Method RS03 (Consult laboratory for field strengths available)

[12/E04]
MIL-STD-462 Method RS03 employing RADHAZ procedures for high level testing (Consult laboratory for field strengths available)

[12/E05]
MIL-STD-462 Method RS05

[12/E07]
MIL-STD-462 Method RS06

[12/E08]
MIL-STD-462 Version D Method RS101

[12/E09]
MIL-STD-462 Version D Method RS103

[12/E10]
MIL-STD-462 Version D Method RS105

[12/E11]
MIL-STD-461 Version E Method RS101

[12/E12]
MIL-STD-461 Version E Method RS103

[12/E13]
MIL-STD-461 Version E Method RS105

Return to NVLAP Program Listing


Return to top of page NVLAP Home | Accredited Laboratories | Fields of Accreditation | Publications/Applications |
Mutual Recognition Arrangements | Assessor Resources | Contact NVLAP
Return to top of page

For questions concerning the National Voluntary Laboratory Accreditation Program, contact us:

National Voluntary Laboratory Accreditation Program, Standards Services Division, NIST, 100 Bureau Drive, Stop 2140, Gaithersburg, MD 20899-2140
Phone: (301) 975-4016, Fax: (301) 926-2884, Email: NVLAP@nist.gov

Date created: July 26, 2002
Last Updated: November 1, 2009

Privacy Statement / Security Notice / Accessibility Statement | Disclaimer | FOIA