Elite Electronic Engineering Inc.NVLAP Lab Code: 100278-0
Address and Contact Information:
1516 Centre Circle
Downers Grove, IL 60515-1082
Contact: Mr. Raymond Klouda
Phone: 630-495-9770
Fax: 630-495-9785
E-Mail: rjklouda@elitetest.com
Send E-Mail to Laboratory: Elite Electronic Engineering Inc.
URL: http://www.elitetest.com
NVLAP Accreditation Information
Listed below is the scope of accreditation for this laboratory as of November 1, 2009. For additional information, contact NVLAP at (301) 975-4016.
Send E-Mail to NVLAP at: NVLAP@nist.gov
Electromagnetic Compatibility & Telecommunications
Accreditation Valid From: October 1, 2009 Through: September 30, 2010
[12/160D21] RTCA/DO-160D (1997)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 21 - Emission of Radio Frequency Energy
[12/160F21] RTCA/DO-160F (2007)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 21 - Emissions of Radio Frequency Energy
[12/60E213] RTCA DO-160E
Section 21.3, RF Emissions, Conducted
[12/60E214] RTCA DO-160E
Section 21.4, RF Emissions, Radiated
[12/61000g] EN 61000-6-3 (2007)
Electromagnetic compatibility (EMC) - Part 6-3: Generic standard - Emission standard for residential, commericial and light industrial environments
[12/CIS11g] IEC/CISPR 11, Ed. 4.1 (2004-06)
Industrial, scientific and medical (ISM) radio-frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurements
[12/CIS14] CISPR 14-1 (March 30, 2000)
Limits and Methods of Measurement of Radio interference Characteristics of Household Electrical Appliances, Portable Tools and Similiar Electrical Apparatus - Part 1: Emissions
[12/CIS14a] EN 55014-1 (1993), A1 (1997), A2 (1999)
[12/CIS14a4] EN 55014-1 (2006)
Electromagnetic Compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
[12/CIS14e] EN 55014-1 (2001) and A1 (2001)
Electromagnetic Compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
[12/CIS22] IEC/CISPR 22 (1997) & EN 55022 (1998) + A1(2000)
Limits and methods of measurement of radio disturbance characteristics of information technology equipment
[12/CIS22c4] EN 55022 (1998) + A1(2000) + A2(2003)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
[12/CIS22j] EN 55022 (2006)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
[12/EM02i] IEC 61000-3-2, Ed. 3.0 (2005-11)
Electromagnetic compatability (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <=16 A per phase)
[12/EM03ii] IEC 61000-3-3, Edition 1.2 (2005-10)
EMC- Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low- voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection
[12/FCC15b] ANSI C63.4 (2003) with FCC Method 47 CFR Part 15, Subpart B
Unintentional Radiators
[12/KN11d] KN11 (2008-5) with RRL Notice No. 2008-3 (May 20, 2008)
Conformity Assessment Procedure for Electromagnetic Interference; With KN 11
[12/KN14b] KN 14-1 (2008-5) with RRL Notice No. 2008-3 (May 20, 2008)
Electromagnetic Compatibility - Requirements for household appliances, electric tools and similar apparatus - Emission
[12/KN22e] KN22 (2008-5) with RRL Notice No. 2008-3 (May 20, 2008)
Conformity Assessment Procedure for Electromagnetic Interference; With KN 22
[12/T51a] AS/NZS CISPR 22 (2004)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
[12/160D16] RTCA/DO-160D (1997)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 16 - Power Input
[12/160D17] RTCA/DO-160D (1997)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 17 - Voltage Spike
[12/160D18] RTCA/DO-160D (1997)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 18 - Audio Frequency Conducted Susceptibility - Power Inputs
[12/160D19] RTCA/DO-160D (1997)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 19 - Induced Signal Susceptibility
[12/160D20] RTCA/DO-160D (1997)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 20 - Radio Frequency Susceptibility (Radiated and Conducted)
[12/160D22] RTCA/DO-160D (1997)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 22 - Lightning Induced Transient Susceptibility
[12/160F15] RTCA/DO 160F (2007)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 15 - Magnetic Effect
[12/160F16] RTCA/DO-160F (2007)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 16 - Power Input
[12/160F17] RTCA/DO-160F (2007)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 17 - Voltage Spike
[12/160F18] RTCA/DO-160F (2007)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 18 - Audio Frequency Conducted Suspceptibility - Power Inputs
[12/160F19] RTCA/DO-160F (2007)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 19 - Induced Signal Susceptibility
[12/160F20] RTCA/DO-160F (2007)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 20 - Radio Frequency Susceptibility (Radiated and Conducted)
[12/160F22] RTCA/DO-160F (2007)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 22 - Lightning Induced Transient Susceptibility
[12/160F25] RTCA/DO-160F (2007)
Environmental Conditions and Test Procedures for Airborne Equipment - Section 25 - Electrostatic Discharge (ESD)
[12/501304a] EN 50130-4 (1995) + A1(1998) & A2(2003)
Alarm systems - Part 4. Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder and social alarm systems
[12/60E05] RTCA DO -160E
Section 5: Temperature
[12/60E06] RTCA DO-160E
Section 6: Humidity
[12/60E15] RTCA DO 160E
Section 15, Magnetic Effects
[12/60E16] RTCA DO160E
Section 16, Power Input
[12/60E17] RTCA DO-160E
Section 17, Voltage Spikes
[12/60E18] RTCA DO-160E
Section 18, Audio Frequency Conducted Susceptibility
[12/60E19] RTCA DO-160E
Section 19, Induced Signal Susceptibility
[12/60E204] RTCA DO-160E
Section 20.4, RF Susceptibility, Conducted
[12/60E205] RTCA DO-160E
Section 20.5, RF Susceptibility, Radiated
[12/60E206] RTCA DO-160E
Section 20.6: RF Susceptability (Radiated Mode Tuned)
[12/60E22] RTCA DO-160E
Section 22, Lightning Induced Transient Susceptibility
[12/60E23] RTCA DO-160E
Section 23,Lightning Direct Effects
[12/60E25] RTCA DO-160E
Section 25, Electrostatic Discharge (ESD)
[12/610006j] EN 61000-6-2 (2005)
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments
[12/61000k] EN 61000-6-1 (2007)
Electromagnetic compatibility (EMC) - Part 6 - 1: Generic standards - Immunity for residential, commercial and light-industrial environments
[12/CIS14i] EN 55014-2 (1997) and IEC/CISPR 14-2 (1997)
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2. Immunity - Product family standard
[12/I01] IEC 61000-4-2, Ed. 1.2 (2001); EN 61000-4-2
Electrostatic Discharge Immunity Test
[12/I01a] IEC 61000-4-2 (1995), A1(1998), A2(2000); EN 61000-4-2(1995)
ESD Immunity Test
[12/I02c] IEC 61000-4-3 (1995), A1(1998), A2(2000)
Radiated, radio-frequency, electromagnetic field immunity test
[12/I02g] IEC 61000-4-3, Ed. 3.0 (2006-02)
Electromagnetic compatibility (EMC) - Part 4-3: Testing measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
[12/I03] IEC 61000-4-4(1995), A1(2000), A2(2001); EN 61000-4-4
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical Fast Transient/Burst Immunity Test
[12/I03c] IEC 61000-4-4, Ed. 2.0 (2004-07)
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
[12/I04a] IEC 61000-4-5(1995),A1(2000); EN 61000-4-5(1995),A1(2001)
Surge Immunity Test
[12/I04c] IEC 61000-4-5, Ed 1.1 (2005-11)
EMC - Part 4-5: Testing and measurement techniques - Surge immunity test
[12/I05a] IEC 61000-4-6 (1996),A1(2000); EN 61000-4-6(1996),A1(2001)
Immunity to Conducted Disturbances, Induced by Radio Frequency Fields
[12/I05f] IEC 61000-4-6, Ed 2.0 (2006-05)
EMC - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
[12/I06] IEC 61000-4-8, Ed. 1.1 (2001); EN 61000-4-8
Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
[12/I06a] IEC 61000-4-8(1993), A1(2000); EN 61000-4-8(1994), A1(2000)
Power Frequency Magnetic Field Immunity Test
[12/I07c] IEC 61000-4-11, Ed. 2 (2004-03) & EN 61000-4-11
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
[12/I08] IEC/CISPR 24 (1997), Amd1, A1(2001); EN 55024 (1998)
Information technology equipment - Immunity characteristics - Limits and methods of measurement
[12/I08a] EN 55024 (1998) + A1 (2001) + A2 (2003)
Information Technology Equipment - Immunity Characteristics - Limits and Methods of Measurement
[12/KN11f] KN 61000-4-11 (2008-5); RRL Notice No. 2008-4 (May 20, 2008)
Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests
[12/KN14c] KN14-2 (2008-5) with RRL Notice No. 2008-4 (May 20, 2008)
Electromagnetic Compatibility - Requirements for household appliances, electric tools and similar apparatus - Immunity
[12/KN24d] KN 24 (2008-5) with RRL Notice No. 2008-4 (May 20, 2008)
Information Technology Equipment - immunity charateristics - limits and methods of measurements
[12/KN2c] KN 61000-4-2 (2008-5); RRL Notice No. 2008-4 (May 20, 2008)
Electrostatic Discharge Immunity Test
[12/KN3c] KN 61000-4-3 (2008-5); RRL Notice No. 2008-4 (May 20, 2008)
Radiated, radio-frequency, electromagnetic field immunity test
[12/KN4c] KN 61000-4-4 (2008-5); RRL Notice No. 2008-5 (May 20, 2008)
Electromagnetic compatibility (EMC): Testing and measurement techniques - Electrical Fast Transient/Burst Immunity Test
[12/KN5c] KN 61000-4-5 (2008-5); RRL Notice No. 2008-4 (May 20, 2008)
Surge Immunity Test
[12/KN6c] KN 61000-4-6 (2008-5); RRL Notice No. 2008-4 (May 20, 2008)
Electromagnetic compatibility (EMC): Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
[12/KN8c] KN 61000-4-8 (2008-5); RRL Notice No. 2008-4 (May 20, 2008)
Power Frequency Magnetic Field Immunity Test
- MIL-STD-462 : Conducted Emissions
[12/A01]
MIL-STD-462 Method CE01
[12/A04]
MIL-STD-462 Method CE02
[12/A06]
MIL-STD-462 Method CE03
[12/A08]
MIL-STD-462 Method CE04
[12/A10]
MIL-STD-462 Method CE06
[12/A12]
MIL-STD-462 Method CE07
[12/A13]
MIL-STD-462 Version D Method CE101
[12/A14]
MIL-STD-462 Version D Method CE102
[12/A15]
MIL-STD-462 Version D Method CE106
[12/A16]
MIL-STD-461 Version E Method CE101
[12/A17]
MIL-STD-461 Version E Method CE102
[12/A18]
MIL-STD-461 Version E Method CE106
[12/A19]
MIL-STD-461 Version F Method CE101
[12/A20]
MIL-STD-461 Version F Method CE102
[12/A21]
MIL-STD-461 Version F Method CE106
- MIL-STD-462 : Conducted Susceptibility
[12/B01]
MIL-STD-462 Method CS01
[12/B02]
MIL-STD-462 Method CS02
[12/B04]
MIL-STD-462 Method CS03/CS04/CS05/CS08
[12/B05]
MIL-STD-462 Method CS06
[12/B06]
MIL-STD-462 Method CS07
[12/B07]
MIL-STD-462 Method CS09
[12/B08]
MIL-STD-462 Method CS10
[12/B09]
MIL-STD-462 Method CS11
[12/B10]
MIL-STD-462 Method CS12
[12/B11]
MIL-STD-462 Method CS13
[12/B12]
MIL-STD-462 Version D Method CS101
[12/B13]
MIL-STD-462 Version D Method CS103
[12/B14]
MIL-STD-462 Version D Method CS104
[12/B15]
MIL-STD-462 Version D Method CS105
[12/B16]
MIL-STD-462 Version D Method CS109
[12/B17]
MIL-STD-462 Version D Method CS114
[12/B18]
MIL-STD-462 Version D Method CS115
[12/B19]
MIL-STD-462 Version D Method CS116
[12/B20]
MIL-STD-461 Version E Method CS101
[12/B21]
MIL-STD-461 Version E Method CS103
[12/B22]
MIL-STD-461 Version E Method CS104
[12/B23]
MIL-STD-461 Version E Method CS105
[12/B24]
MIL-STD-461 Version E Method CS109
[12/B25]
MIL-STD-461 Version E Method CS114
[12/B26]
MIL-STD-461 Version E Method CS115
[12/B27]
MIL-STD-461 Version E Method CS116
[12/B28]
MIL-STD-461 Version F Method CS101
[12/B29]
MIL-STD-461 Version F Method CS103
[12/B30]
MIL-STD-461 Version F Method CS104
[12/B31]
MIL-STD-461 Version F Method CS105
[12/B32]
MIL-STD-461 Version F Method CS106
[12/B33]
MIL-STD-461 Version F Method CS109
[12/B34]
MIL-STD-461 Version F Method CS114
[12/B35]
MIL-STD-461 Version F Method CS115
[12/B36]
MIL-STD-461 Version F Method CS116
- MIL-STD-462 : Radiated Emissions
[12/D01]
MIL-STD-462 Method RE01
[12/D02]
MIL-STD-462 Method RE02
[12/D03]
MIL-STD-462 Method RE03
[12/D04]
MIL-STD-462 Version D Method RE101
[12/D05]
MIL-STD-462 Version D Method RE102
[12/D06]
MIL-STD-462 Version D Method RE103
[12/D07]
MIL-STD-461 Version E Method RE101
[12/D08]
MIL-STD-461 Version E Method RE102
[12/D09]
MIL-STD-461 Version E Method RE103
[12/D10]
MIL-STD-461 Version F Method RE101
[12/D11]
MIL-STD-461 Version F Method RE102
[12/D12]
MIL-STD-461 Version F Method RE103
- MIL-STD-462 : Radiated Susceptibility
[12/E01]
MIL-STD-462 Method RS01
[12/E02]
MIL-STD-462 Method RS02
[12/E04]
MIL-STD-462 Method RS03 employing RADHAZ procedures for high level testing (Consult laboratory for field strengths available)
[12/E05]
MIL-STD-462 Method RS05
[12/E07]
MIL-STD-462 Method RS06
[12/E08]
MIL-STD-462 Version D Method RS101
[12/E09]
MIL-STD-462 Version D Method RS103
[12/E10]
MIL-STD-462 Version D Method RS105
[12/E11]
MIL-STD-461 Version E Method RS101
[12/E12]
MIL-STD-461 Version E Method RS103
[12/E13]
MIL-STD-461 Version E Method RS105
[12/E15]
MIL-STD-461 Version F Method RS101
[12/E16]
MIL-STD-461 Version F Method RS103
- Product Safety Test Methods
[12/CSA03] CAN/CSA E60065
Audio, Video and Similar Electronic Apparatus - Safety Requirements
- Telecommunications Test Methods
[12/T01]
Terminal Equipment Network Protection Standards, FCC/ACTA Method - 47 CFR Part 68 - Analog and Digital
[12/T01a]
68.302 (Par. c,d,e,f) Environmental simulation; 68.304 Leakage current limit.; 68.306 Hazardous voltage limit.; 68.308 Signal power limit.; 68.310 Longitudinal balance limit.; 68.312 On-hook impedance limit.; 68.314 Billing protection
[12/T01b]
68.316 and 68.317 Hearing Aid Compatibility: technical standards
[12/T01c]
68.302 Environmental simulation (Par. a,b)
[12/T1TRQ6] T1.TRQ.6 (2001)
Technical Requirements for SHDSL, HDSL2, HDSL4, Digital Subscriber Line Terminal Equipment to Prevent Harm to the Telephone Network
[12/TIA31B] TIA/EIA TSB-31-B (1998)
Part 68 Rational and Measurement Guidelines
[12/TIA968] ANSI/TIA-968-A (2003)
Telephone Terminal Equipment, Technical Requirements for Connection of Terminal Equipment to the Telephone Network
[12/TIA968a] ANSI/TIA-968-A-1 (2003)
Telephone Terminal Equipment, Technical Requirements for Connection of Terminal Equipment to the Telephone Network - Addendum 1
[12/TIA968b] ANSI/TIA-968-A-2 (2004)
Telephone Terminal Equipment, Technical Requirements for Connection of Terminal Equipment to the Telephone Network - Addendum 2
[12/TIA968c] ANSI/TIA-968-A-3 (2005)
Telephone Terminal Equipment, Technical Requirements for Connection of Terminal Equipment to the Telephone Network - Addendum 3
Return to NVLAP Program Listing
NVLAP Home |
Accredited Laboratories |
Fields of Accreditation |
Publications/Applications |
Mutual Recognition Arrangements |
Assessor Resources |
Contact NVLAP 
For questions concerning the National Voluntary Laboratory Accreditation Program, contact us:
National Voluntary Laboratory Accreditation Program, Standards Services Division, NIST, 100 Bureau Drive, Stop 2140, Gaithersburg, MD 20899-2140
Phone: (301) 975-4016, Fax: (301) 926-2884, Email: NVLAP@nist.gov
Date created: July 26, 2002
Last Updated: November 1, 2009
Privacy
Statement / Security Notice / Accessibility Statement | Disclaimer
| FOIA
|