Technology Services, National Voluntary Laboratory Accreditation Program, NIST Go to Technology Services Home Page Go to NIST Home Page Go to National Voluntary Laboratory Accreditation Program Home Page Go to Directory of Accredited Laboratories Go to Fields of Accreditation Go to Publications/Applications Go to Mutual Recognition Arrangements Go to Assessor Resources Contact National Voluntary Laboratory Accreditation Program

Underwriters Laboratories, Inc.

NVLAP Lab Code: 100255-0


Address and Contact Information:

1285 Walt Whitman Road
Melville, NY 11747-3081
Contact: Mr. Rick A. Titus
Phone: 847-664-3281
Fax: 847-313-3281
E-Mail: Rick.A.Titus@us.ul.com
Send E-Mail to Laboratory: Underwriters Laboratories, Inc.
URL: http://www.ul.com

NVLAP Accreditation Information

Listed below is the scope of accreditation for this laboratory as of November 1, 2009. For additional information, contact NVLAP at (301) 975-4016.

Send E-Mail to NVLAP at: NVLAP@nist.gov


Electromagnetic Compatibility & Telecommunications

Accreditation Valid From: October 1, 2009 Through: September 30, 2010

  • Emissions Test Methods

[12/13766] ISO 13766 (1999)
Earth-moving machinery -- Electromagnetic compatibility

[12/50366] EN 50366 (2003)
Household and similar electrical appliances. Electromagnetic fields. Methods for evaluation and measurement

[12/50366a] EN 50366 (2006)
Household and similar electrical appliances. Electromagnetic fields. Methods for evaluation and measurement

[12/55103a] EN 55103-1 (1996)
Electromagnetic compatibility - Product family standard for audio, video, audio-visual and entertainment lighting control apparatus for professional use - Part 1: Emission

[12/60699a] BS EN 60669-2-1 (2000)
Switches for household and similar fixed electrical installations - Part 2-1: Particular requirements - Electronic switches

[12/610006k] IEC 61000-6-4 (2006-07)
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments

[12/61000g] EN 61000-6-3 (2007)
Electromagnetic compatibility (EMC) - Part 6-3: Generic standard - Emission standard for residential, commericial and light industrial environments

[12/61326d] IEC 61326-1 (2005-12)
Electrical equipment for measurement, control and laboratory use - EMC requirements

[12/CIS11g] IEC/CISPR 11, Ed. 4.1 (2004-06)
Industrial, scientific and medical (ISM) radio-frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurements

[12/CIS11h] AS/NZS CISPR 11 (2004)
Industrial, scientific and medical (ISM) radio frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement

[12/CIS13aa] CISPR 13, Edition 4.2 (2006-03)
Sound and broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement

[12/CIS13bb] EN 55013 (2001) + A1 (2003) + A2 (2006)
Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement

[12/CIS13c] CISPR 13 (2003) + Amdt 1(2003) & AS/NZS CISPR 13 (2004)
Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement

[12/CIS14a4] EN 55014-1 (2006)
Electromagnetic Compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission

[12/CIS14gg] CNS 13783-1 (2004)
Electromagnetic Compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission

[12/CIS14h] AS/NZS CISPR 14.1 (2003)
Electromagnetic Compatibility - Requirements for household appliances, electric tools and similar apparatus - Emission

[12/CIS14x1] IEC/CISPR 14-1, Ed. 5.0 (2005)
Electromagnetic Compatibility - Requirements for Household Appliances, Electric Tools and Similar Apparatus - Part 1: Emission

[12/CIS15bb] CNS 13439 (2006)
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

[12/CIS22c4] EN 55022 (1998) + A1(2000) + A2(2003)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

[12/CIS22f] CNS 13438 (2006)
LImits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment

[12/CIS22i] IEC/CISPR 22, Edition 5.2 (2006-03)
Limits and Methods of Measurement of Radio Disturbance Characteristics of Information Technology Equipment

[12/CIS22j] EN 55022 (2006)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

[12/EM02h] JIS C 61000-3-2:2005
Electromagnetic Compatibility (EMC) - Part 3-2: Limits - Limits for Harmonic Current Emissions (Equipment Input Current <= 20 A per Phase)

[12/EM02i] IEC 61000-3-2, Ed. 3.0 (2005-11)
Electromagnetic compatability (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <=16 A per phase)

[12/EM02j] EN 61000-3-2 (2006)
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase)

[12/EM03ii] IEC 61000-3-3, Edition 1.2 (2005-10)
EMC- Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low- voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection

[12/EM03j] AS/NZS 2279.3 (2001)
EMC - Part 3-3: Limits - Limitations of voltage changes, voltage flucuations and flicker, in public low-voltage supply-systems, for equipment with rated current <=16 A per phase and not subject to conditional connections

[12/EM12a] IEC 61000-3-12 (2004) & EN 61000-3-12 (2005)
Electromagnetic Compatibility (EMC) - PART 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current greater than 16 A and less than or equal to 75 A

[12/EN11] EN 61000-3-11, Rev 01, Feb 2001
Electromagnetic Compatibility (EMC) Limits, Limitation of Voltage Changes, Voltage Fluctuations and Flicker in public low-voltage supply systems - Equipment with rated voltage current < 75 A and subject to conditional connection

[12/FCC15c] ANSI C63.4 (2003) with FCC Method 47 CFR Part 15, Subpart C
Intentional Radiators

[12/ICES001] ICES-001
Industrial, Scientific and Medical (ISM) Radio Frequency Generators

[12/ICES005] ICES-005 Issue 5 (November 1, 1998)
Radio Frequency Lighting Devices.

[12/JIS1806] JIS C 1806-1 (2001)
Electrical equipment for measurement, control and laboratory use - EMC requirements

[12/KN13a] KN13 (Annex 4) with RRL Notice No. 2007-100 (Dec. 26, 2007)
Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement

[12/KN14a] KN14 (Annex 5) with RRL Notice No. 2007-100 (Dec. 26, 2007)
Electromagnetic Compatibility - Requirements for household appliances, electric tools and similar apparatus - Emission

[12/KN22d] KN22 (Annex 8) with RRL Notice No. 2008-04 (Feb. 11, 2008)
Conformity Assessment Procedure for Electromagnetic Interference; With KN 22 (Annex 8)

[12/Kn11d] KN11 (Annex 3) with RRL Notice No. 2008-02
Conformity Assessment Procedure for Electromagnetic Interference; With KN 11 (Annex 3)

[12/T51b] AS/NZS CISPR 22, 3rd Edition (2006)
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

[12/VCCId] Agreement of VCCI V-3 (2008.04)
Agreement of Voluntary Control Council for Interference by Information Technology Equipment - Technical Requirements: V-3/2008.04

  • Immunity Test Methods

[12/610006g] IEC 61000-6-2, 1st edition (1999-01)
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments

[12/610006h] IEC 61000-6-1, 2nd edition (2005-03)
Electromagnetic compatibility (EMC) - Part 6: Generic standards - Section 1: Immunity for residential, commercial and light-industrial environments

[12/610006i] IEC 61000-6-2, Edition 2.0 (2005-01)
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments

[12/610006j] EN 61000-6-2 (2005)
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments

[12/61000k] EN 61000-6-1 (2007)
Electromagnetic compatibility (EMC) - Part 6 - 1: Generic standards - Immunity for residential, commercial and light-industrial environments

[12/61326a4] EN 61326-1(2006)
Electrical equipment for measurement, control and laboratory use - EMC requirements

[12/61326j] IEC 61326-2-6, Ed. 1.0 (2005-12)
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment

[12/61547a] IEC 61547 (1995)
Equipment for general lighting purposes EMC immunity requirements

[12/CIS20c] EN 55020 (2007-01)
Sound and television broadcast receivers and associated equipment - immunity characteristics - Limits and methods of measurement

[12/CIS24b] AS/NZS CISPR 24 (2002)
Information technology equipment - Immunity characteristics - Limits and methods of measurement

[12/I01] IEC 61000-4-2, Ed. 1.2 (2001); EN 61000-4-2
Electrostatic Discharge Immunity Test

[12/I01c] EN 61000-4-2 +A1(1998) +A2(2001)
Electrostatic Discharge Immunity Test

[12/I02h] EN 61000-4-3 (2006)
Radiated, radio-frequency, electromagnetic field immunity test

[12/I03] IEC 61000-4-4(1995), A1(2000), A2(2001); EN 61000-4-4
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical Fast Transient/Burst Immunity Test

[12/I03c] IEC 61000-4-4, Ed. 2.0 (2004-07)
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test

[12/I04aa] IEC 61000-4-5, Ed. 2.0 (2005-11); EN 61000-4-5
Electromagnetic Compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test

[12/I05f] IEC 61000-4-6, Ed 2.0 (2006-05)
EMC - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields

[12/I05g] EN 61000-4-6 (2006)
Immunity to Conducted Disturbances, Induced by Radio Frequency Fields

[12/I06] IEC 61000-4-8, Ed. 1.1 (2001); EN 61000-4-8
Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test

[12/I06c] EN 61000-4-8 (1993) + A1 (2001)
Power Frequency Magnetic Field Immunity Test

[12/I07c] IEC 61000-4-11, Ed. 2 (2004-03) & EN 61000-4-11
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests

[12/I07f] EN 61000-4-11 (2004)
Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests

[12/I08] IEC/CISPR 24 (1997), Amd1, A1(2001); EN 55024 (1998)
Information technology equipment - Immunity characteristics - Limits and methods of measurement

[12/KN11e] KN 61000-4-11 (Annex 7); RRL No. 2007-101 (Dec. 26, 2007)
Conformity Assessment Procedure for Electromagnetic Interference

[12/KN24b] KN24 (Annex 11) with RRL Notice No. 2007-101 (Dec. 26, 2007)
Information Technology Equipment - immunity charateristics - limits and methods of measurements

[12/KN2b] KN 61000-4-2 (Annex 1);RRL Notice No. 2007-101(Dec. 26 2007)
Electrostatic Discharge Immunity Test

[12/KN3b] KN 61000-4-3 (Annex 2); RRL Notice No. 2007-101(Dec.26,2007)
Radiated, radio-frequency, electromagnetic field immunity test

[12/KN4b] KN 61000-4-4 (Annex 3); RRL No. 2007-101 (Dec. 26, 2007)
Electromagnetic compatibility (EMC): Testing and measurement techniques - Electrical Fast Transient/Burst Immunity Test

[12/KN5b] KN 61000-4-5 (Annex 4); RRL No. 2007-101 (Dec. 26, 2007)
Surge Immunity Test

[12/KN6b] KN 61000-4-6 (Annex 5); RRL No. 2007-101 (Dec. 26, 2007)
Electromagnetic compatibility (EMC): Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields

[12/KN8b] KN 61000-4-8 (Annex 6); RRL No. 2007-101 (Dec. 26, 2007)
Power Frequency Magnetic Field Immunity Test

  • Product Safety Test Methods

[12/4117] AS/NZS 4117 (1999)
Surge protective devices for telecommunications applications

[12/60601a] IEC 60601-1-2, Ed1(1993);Ed2(2001-09); JIS T0601-1-2(2002.7)
Medical electrical equipment - Part 1 and Part 1-2: General requirements for safety: Collateral standard: EMC - Requirements and tests

[12/60601aa] IEC 60601-1-2, Ed 2.1 (2004-11) & EN 60601-1-2 (2002)
Medical electrical equipment - Part 1-2: General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and tests

[12/60601ab] IEC 60601-1-2, Ed. 3.0 (2007)
Medical electrical equipment - Part 1-2: General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and tests

[12/60601bb] IEC 60601-2-2 Ed. 4.0 (2006)
Medical electrical equipment - Part 2-2, Particular requirements for the safety of high frequency surgical equipment

[12/60601i] IEC 60601-2-4:2005; EN 60601-2-4:2003
Particular requirments for the safety of cardiac defribrillators

[12/60601k] IEC 60601-2-25:1993 + A1:1999, EN 60601-2-25:1993 + A1:1999
Particular requirments for the safety of electrocardiographs

[12/60601m] IEC 60601-2-30:1999, EN 60601-2-30:2000
Particular requirements for the safety including essential performance, of automatic cycling non-invasive blood pressure monitoring equipment

[12/60601o] IEC 60601-2-34:2000, EN 60601-2-34:2001
Particular requirements for the safety, including essential performance, of invasive blood pressure monitoring equipment

[12/60601r] IEC 60601-2-49:2006, EN 60601-2-49:2001
Particular requirements for the safety of multifunction patient monitoring equipment

[12/60601s] IEC 60601-2-24, Ed. 1 (1998)
Medical electrical equipment - Part 2-24: Particular requirements for the safety of infusion pumps and controllers

[12/60601t] EN 60601-2-24 (1998)
Medical electronic equipment Part 2-24: Particular requirements for the safety of infusion pumps and controllers

[12/60601u] IEC 60601-2-37 (2001) + A1 (2004) + A2 (2005)
Medical electrical equipment - Part 2-37: Particular requirements for the safety of ultrasonic medical diagnostic and monitoring equipment

[12/60601v] EN 60601-2-37 (2001) + A1 (2004) + A2 (2005)
Medical electrical equipment - Part 2-37: Particular requirements for the safety of ultrasonic medical diagnostic and monitoring equipment

[12/60601w] EN 60601-2-2 (2001)
Medical electrical equipment - Part 2-2, Particular requirements for the safety of high frequency surgical equipment

[12/60601x] IEC 60601-2-18, Ed. 2 (1996), + A1 (2000)
Medical electrical equipment - Part 2: Particular requirements for the safety of endoscopic equipment

[12/T50a] AS/NZ 60950 (2000)
Safety of information technology equipment

[12/T50b] AS/NZS 60950.1 (2003)
Information technology equipment - Safety - Part 1: General requirements (IEC 60950-1: 2001, MOD)

[12/T50c] AS/NZS 60950.1 (2003) + A1 (2006)
Information technology equipment - Safety - Part 1: General Requirements

  • RF Exposure Test Methods (SAR & MPE)

[12/62233a] EN 62233 (2008)
Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure

  • Radio Test Methods

[12/300220d] ETSI EN 300 220-1 V2.1.1 (2006-04)
Electromagnetic Compatibility Radio Spectrum Matters; Short Range Devices; Radio Equipment to be used in the 25 MHz to 1,000 MHz Frequency Range with Power Levels Ranging up to 500mW; Part 1: Technical Characteristics and Test Methods

[12/300220e] ETSI EN 300 220-2 V2.1.1 (2006-04)
ERM; Short Range Devices; Radio Equipment to be used in the 25MHz to 1,000 MHz Frequency Range with Power Levels Ranging up to 550 mW; Part 2: Supplementary Parameters Not Intended for Conformity Purposes

[12/300328g] ETSI EN 300 328 V1.7.1 (2006-10)
ERM; Wideband Transmission Systems; Data transport equipment operating in the 2.4 GHz ISM band and using wide band modulation techniques; Harmonized EN covering essential requirements under article 3.2 of the R&TTE Directive

[12/300330b] ETSI EN 300 330-2 v1.1.1 (2001-06)
ERM; Short Range Devices (SRD); Radio equipment in the frequency range 9kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Part 2: Harmonized EN under article 3.2 of the R&TTE Directive

[12/300330c] ETSI EN 300 330-1 V1.5.1 (2006-04)
ERM; Short Range Devices; Radio Equipment in the Frequency Range 9kHz to 25 MHz and Inductive Loop Systems in the Frequency Range 9kHz to 30 MHz; Part 1: Technical Characteristics and Test Methods

[12/300330d] ETSI EN 300 330-2 V1.3.1 (2006-04)
ERM; Short Range Devices (SRD); Radio Equipment in the Frequency Range 9kHz to 30 MHz; Part 2: Harmonized EN Under Article 3.2 of the R&TTE Directive

[12/300440d] ETSI EN 300 440-2 v1.2.1 (2008-03)
Electromagnetic compatibility and Radio spectrum Matters (ERM); Short range devices; Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Part 2: Harmonized EN under article 3.2 of the R&TTE Directive

[12/301489b] ETSI EN 301 489-3 v1.4.1 (2002-08)
Electromagnetic compatibility and Radio spectrum Matters; ElectroMagnetic Compatibility standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 40 GHz

[12/301489z] ETSI EN 301 489-1 v1.6.1 (2005-09)
ERM; ElectroMagnetic Compatability (EMC) Standard for Radio Equipment and Services; Common Technical Requirements

[12/AS4268c] AS/NZS 4268 (2003) + A1 (2005)
Radio Equipment and Systems - Short Range Devices - Limits and Methods of Measurement

[12/HKTA35] HKTA 1035, Issue 3 (April 2005)
Performance Specification for Low Power Device

[12/HKTA39] HKTA 1039, Issue 2 (April 2005)
Performance Specification for Radiocommunications Apparatus Operating in the 2.4 Ghz or 5 Ghz Band and Employing Frequency Hopping or digital Modulation

[12/HKTA49] HKTA 1049, Issue 1 (April 2005)
Performance Specification for Radio Frequency Identification (RFID) Equipment Operating in the 865 - 868 MHz and/or 920 - 925 MHz Bands

[12/IDA48b] IDA TS SRD Issue 1, Revision 3 (January 2008)
Technical Specification for Short Range Devices

[12/RSS210a] RSS-210, Issue 7 (June 2007)
Low Power Licence-Exempt Radiocommunication Devices (All Frequency Bands): Category 1 Equipment

[12/RSSG2] RSS-Gen, Issue 2 (June 2007)
General Requirements and Information for the Certification of Radiocommunication Equipment

[12/RSSgen] RSS-Gen, Issue 1 (Sept. 2005)
General Requirements and Information for the Certification of Radiocommunication Equipment

  • Telecommunications Test Methods

[12/300019d] ETSI EN 300-019-2-4 v2.2.2 (2003-04): Environmental
Engineering: Environmental Conditions and Environmental Tests for Telecommunications Equipment; Part 2-4: Specification of Environmental Tests; Sationary use at Non-Weatherprotected Locations

[12/300019e] ETSI EN 300 019-1-0 v2.1.2 (2003-09): Environmental
Engineering: Environmental Conditions and Environmental Tests for Telecommunications equipment; Part 1-0; Classification of Environmental Conditions

[12/300386a] EN 300 386 V1.2.1 (2000-03)
Electromagnetic compatibility and radio spectrum matter (ERM); Telecommunication network equipment; Electromagnetic Compatibility (EMC) requirements

[12/300386b] EN 300 386 V1.3.1 (2001-09)
Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirements

[12/300386d] EN 300 386-2 V1.1.3 (1997-12)
Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirements; Part 2: Product family standard

[12/300386f] ETSI EN 300 386 V1.3.3 (2005-04)
Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirements

[12/300386g] ETSI EN 300 386 V1.4.1 (2008-02)
Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment; ElectroMagnetic Compatibility (EMC) requirements

[12/CS03a] Industry Canada CS-03, Issue 9, Amendment 1 (2005)
Compliance Specification for Terminal Equipment, Terminal Systems, Network Protection Devices, Connection Arrangements and Hearing Aids Compatibility (Sections I, II, V only)

[12/GR1089] GR-1089-CORE, Issue 3 (October 2002)
Electromagnetic Compatibility and Electrical Safety - Generic Criteria for Network Telecommunications Equipment

[12/GR1089b] GR-1089-CORE, Issue 4 (June 2006)
EMC and Electrical Safety - Criteria for Network Telecom Equipment (sections 2.1, 2.2, 3.2, 3.2.3, 3.2.4, 3.3, 3.3.1, 4.5, 4.5A, 5.2, 5.3, 6.0, 8.0, 9.0, 10.0)

[12/GR63c] GR-63-CORE, Issue 2 (April 2002)
NEBS (TM) Requirements: Physical Protection

[12/GR63f] GR-63-CORE, Issue 3 (March 2006)
NEBS (TM) Requirements: Physical Protection (sections 5.1.1.1, 5.1.1.2, 5.1.1.3, 5.1.2, 5.1.2a, 5.1.3, 5.1.4, 5.1.5, 5.3.1, 5.3.2, 5.4.1.4, 5.4.1.5a, 5.4.1.5b, 5.4.2, 5.4.3, 5.5.3, 5.5.3a, 5.6, 5.7)


Energy Efficient Lighting Products

Accreditation Valid From: October 1, 2009 Through: September 30, 2010

  • Color Measurements

[22/C01] IES LM-58
Spectroradiometric Measurements

  • Electrical Measurements

[22/E01] IES LM-9
Fluorescent Lamps - Electrical Measurements

[22/E02] IES LM-45
Incandescent Lamps - Electrical Measurements

[22/E03] IES LM-51
High Intensity Discharge (HID) Lamps - Electrical Measurements

[22/E04] IES LM-66
Single-Ended Compact Fluorescent Lamps - Electrical Measurements

[22/E05] ANSI C78.375
Fluorescent Lamps - Electrical Measurements

[22/E06] ANSI C78.386
Mercury Lamps - Measurement of Characteristics

[22/E07] ANSI C78.387
Metal-Halide Lamps - Measurement of Characteristics

[22/E08] ANSI C78.388
High Pressure Sodium Lamps - Measurement of Characteristics

  • Life Tests

[22/L01] IES LM-40
Fluorescent Lamps - Life Test Performance

[22/L04] IES LM-65
Single-Ended Compact Fluorescent Lamps - Life Test Performance

  • Photometric Measurements

[22/P01a] IES LM-9 (Total Flux)
Fluorescent Lamps - Photometric - Total Flux Measurements

[22/P02a] IES LM-20 (Total Flux)
Reflector Type Lamps - Photometric - Total Flux Measurements

[22/P03a] IES LM-45 (Total Flux)
Incandescent Lamps - Photometric - Total Flux Measurements

[22/P04a] IES LM-51 (Total Flux)
High-Intensity Discharge Lamps - Photometric - Total Flux Measurements

[22/P05a] IES LM-66 (Total Flux)
Single-Ended Compact Fluorescent Lamps - Photometric - Total Flux Measurements

Return to NVLAP Program Listing


Return to top of page NVLAP Home | Accredited Laboratories | Fields of Accreditation | Publications/Applications |
Mutual Recognition Arrangements | Assessor Resources | Contact NVLAP
Return to top of page

For questions concerning the National Voluntary Laboratory Accreditation Program, contact us:

National Voluntary Laboratory Accreditation Program, Standards Services Division, NIST, 100 Bureau Drive, Stop 2140, Gaithersburg, MD 20899-2140
Phone: (301) 975-4016, Fax: (301) 926-2884, Email: NVLAP@nist.gov

Date created: July 26, 2002
Last Updated: November 1, 2009

Privacy Statement / Security Notice / Accessibility Statement | Disclaimer | FOIA